Lumascape LS602 Instructions

Narrow pole extension

Advertisement

IMPORTANT INSTRUCTIONS
A
START
For Installation: LS602 Narrow Pole Extension
HERE
Warning: The Luminaire should only be used complete with its protective shield (cover)
LS192-1A
1

INSTALLATION

1.
Align the end of the cable protruding from the main
pole with an end from the extra length of cable
supplied.
2.
Split both ends down the centre to a length of
approximately 40mm (1.57in) so that there are now
4 cables. Strip the ends of all four cables back
approx. 20mm (0.79in).
3.
Note the cable is indexed.(ie. one side is marked,
the other is not) Take the two indexed cables and
very lightly twist the strands together. Fit the
supplied yellow Scotch lock whilst applying
pressure. Keep twisting until very tight. Repeat this
process for the remaining two wires.
4.
Take the now extended length of cable and insert
into the reduced end of the extra extension pole
supplied.
5.
Place the end of the main pole over the reduced
section of the extension piece (Fig. C and D).
6. Using a 3.3mm (0.13in) drill bit, drill a hole 18mm
(0.71in) up from the end of the main pole through
both pole walls. Ensure the drill bit is protruding only
a small distance from the drill chuck. This is to
prevent the internal cable from being damaged by
the drill bit (Fig. E).
7. Using the supplied stainless steel self tapping screw,
insert into drilled hole and firmly tighten being careful
not to strip the thread.
LUMASCAPE
LUMASCAPE
HEAD OFFICE
SYDNEY - NSW
T 07 3286 2299 F 07 3286 6599
T 02 9519 6860 F 02 9519 8834
Lumascape USA Inc.
©
2006
LS192-2A
www.lumascape.com
H.I. LIGHTING
LUMASCAPE
LUMASCAPE AGENT - WA
MELBOURNE - VIC
T 03 9686 1900 F 03 9686 1700
T 08 9321 5422 F 08 9321 5881
MODELS
UL available
L U
R
LS782A
LS112A
FIGURE A
Þ
18MM (0.71IN)
LIGHTING PARTNERS AUSTRALIA
NQ LIGHTING
LUMASCAPE AGENT - SA
LUMASCAPE AGENT - NTH QLD
T 08 8232 0074 F 08 8232 0076
T 07 4031 4490 F 07 4031 5933
LS602 Narrow Pole Extension
F
1m
A.C.N. 010 572 773
t 90 C
t 90 C
Lumascape USA Inc.
1300 Industrial Rd., Unit #19
San Carlos, CA 94070, USA
T 1-(650)-595-LUMA(5862)
F 1-(650)-595-5820
E info@lumascape.com
W www.lumascape.com
Free Call
1-866-695-LUMA(5862)
US & Canada
LS132A
FIGURE B
FIGURE C
Further
information
over page
ECC LIGHTING
LUMASCAPE USA INC
LUMASCAPE AGENT - NZ
Free Call 1-866-695-LUMA(5862)
T 1-(650)-595-LUMA(5862) 1-(650)-595-5820
T 09 379 9680 F 09 308 9328
C794US - 2006_11_REV-002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LS602 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lumascape LS602

  • Page 1 IMPORTANT INSTRUCTIONS Lumascape USA Inc. 1300 Industrial Rd., Unit #19 San Carlos, CA 94070, USA START For Installation: LS602 Narrow Pole Extension T 1-(650)-595-LUMA(5862) HERE F 1-(650)-595-5820 E info@lumascape.com Warning: The Luminaire should only be used complete with its protective shield (cover) W www.lumascape.com...
  • Page 2 Do not operate the luminaires with a missing or damaged parts. Replace any cracked protective shield Use only lamp type, voltage and wattage as specifi ed by Lumascape on the product label. Use only genuine Lumascape parts to replace damaged or missing components.
  • Page 3 Figure 8 PVC Cable Excessive voltage drop causes lamps to Figure 8 PVC Cable have a low light output. The following charts and illustrations apply only to Lumascape supplied cable. The distance and wattage shown are maximum and 4.2mm 5.4mm 6.3mm should not be exceeded.

This manual is also suitable for:

Ls192-1aLs192-2aLs782aLs112aLs132a

Table of Contents