Gas Supply Requirements; Connect The Gas Supply Line - Whirlpool LWF5370 Instructions Manual, Installation And Use Manual

Table of Contents

Advertisement

Available languages

Available languages

Gas Supply Requirements

This stove is prepared to work with a moving LP gas tank or a
fixed LP gas tank.
To use your stove with natural gas you should contact Whirlpool
Service to change the nozzle and make the necessary
adjustments. See the "Service" section in page 31.
NOTE:
The gas type used for this range is LP. If you wish to use Natural gas with this range you will need a conversion kit according to
the following table. This kit can be ordered from the Authorized Whirlpool Solution Center. If you don't follow theses indications your stove
will generate soot and will require cleaning service which is not covered by the warranty of this product.
LWF5050
LWF5150
LWF5370
LWF5470

Connect the Gas Supply Line

A combination of fittings and pipes must be used to connect the stove to the existing gas supply line. Your connection may be different than
the diagram below, according to the supply line type, size and location.
1.
To connect your stove use the material specified on the diagram below.
Supply line piping
Integrated to stove
2.
Once you have connected the stove to the gas supply line, TURN ON the shutoff valve and test all
connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
3.
Check the cooper piping for kinks or other damage so the gas flows freely throw the pipe.
DON'T USE A LIGHTER TO LOOK FOR GAS LEAKS.
DON'T USE PLASTIC HOSES FOR THE CONNECTION TO THE SUPPLY LINE,
EVEN THE FLEXIBLE METAL TUBING, LEAKS MAY OCCUR.
Recommendations
If the installation is not new, clean the pipes to avoid
clogging the burner nozzles.
To facilitate the movement of the appliance, the installer
should make a coil with the flexible copper piping and
install a shutoff valve in the supply line. The valve should
be installed separate from the range and accessible for
whoever is operating the range.
14-Sep-2015 11:56:11 EDT | RELEASED
OPERATING LP GAS PRESSURE
2.75 kPa; 2750 Pa; 27.5 mbar; 28 cm WATER COLUMN
OPERATING NATURAL GAS PRESSURE
1.76 kPa; 1760 Pa; 17.6 mbar; 18 cm WATER COLUMN
Model
Coupling/Nipple
3/8" NPT (9.5 mm)
NOTE: The materials and accessories shown here are not included with the appliance.
NOTE: Your stove may include:
1.- Supply line piping
In some European factories the letter "W" of the part code mentioned herein will be automatically
The qualified technician should make the conversion on the
nozzles of each cooktop burner; the technician must test the
connection and the gas pressure in the oven, the values should
be like the following:
Conversion kit LP gas – Natural gas
W10513462
W10604734
enough to connect to supply line
Copper piping with conical
fittings 3/8" (9.5 mm)
Shutoff valve 3/8"
Always use the correct piping and gas regulators according
to the local codes.
Check the piping and gas regulators, replace if necessary.
Always check the tightness of the connections during
installation.
If you move the range, make sure to gas pipe doesn't get
kinked or damaged.
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")
Copper piping with conical
fittings 3/8" (9.5 mm) long
(9.5 mm)
Coupling/Nipple
3/8" NPT (9.5 mm)
Gas
regulator
19