Troubleshooting - Bryston BDA-3 Service Bulletin

Hide thumbs Also See for BDA-3:

Advertisement

9.
Verify Firmware
The BDA-3 page should automatically
refresh. The bottom of the page lists
a variety of fields. Check that your
firmware now reads
Version: u2020.06c

Troubleshooting

BDA-3 appears to reboot but cannot be found on my.bryston.com or IP address leads to page not found error
It is likely that you updated with the wrong file. Locate your IP address. go to http://(your ip address)/upload.
htm where (your ip address) is your BDA-3's IP address. Example: http://192.168.1.5/upload.htm
If your serial number is less than 001085, start with step 4 and follow instructions through the end. If your
serial number is greater than or equal to 001085, start with step 4 but use file , then skip 5-8.
Can't find IP Address
1. From the front panel, select any input besides USB2 (optical, for instance)
2. Press USB2 5 times in a row
3. Press USB2 several more times. After each time, take note of which input LED lights up. Each light corre-
sponds to a number between 0 and 9 with OPTO being 0 and USB2 being 9. The sequential readout of LEDs
after each press of USB2 will spell your IP address.