Download Print this page

Installation; Setting Environment - Haier FCD-JTSA50-III User Manual

Little sea-ox household electric water heater
Hide thumbs Also See for FCD-JTSA50-III:

Advertisement

Setting Environment

Do not set it at place where is too cold and
may freeze.
Do not use as floorstanding appliance.
Do not install to places without sewer.
The original pipeline of the water heater is an organic part of "PTO 0". Do not remove it by yourself.
Otherwise we will not take responsibility for the injure and loss caused by the safety trouble occurred therefrom.
Description of the Symbols
Never do that
Be sure to act as per instructions
Do not set at outdoor places.
Please mount it to firm and reliable wall.
In case connecting water heater with water drain hose,
connect the drain hose to the inlet of the sewer to
avoid polluting by splashing.
8 5

Installation

Be sure to have it installed by installation staff of the after service
department, or the appointed staff. It adopts wall-mounting installation.
Make four holes with diameter of 12mm and depth 65mm with churn drill on
the wall as per the installation dimension drawing. Insert the bolts into the
holes. Then lift the water heater, set the wall-mounting rack on the bolt.
Set the gasket and fasten the nut. Install the accessories including safety
valve etc. as indicated in Figure 2. Remember to seal with rubber tape to
avoid water leakage.
To facilitate the installation and dismantling, it is suggested to add G 1/2'
flexible nut at the suitable position of the water inlet and outlet pipe
separately. Confirm the position needing water supply. Connect the water
inlet/outlet pipe and tap water pipe to the position respectively.
The hot water pipe shall not be too long to reduce the heat losses.
Please reserve some space in installation for the future maintenance.
(Figure 2) for reference in installation only
Cold water
Hot water
outlet valve
outlet valve
Mixing valve
Connection and use of safety valve:
The safety valve should be connected to the cold water inlet pipe. Please
check carefully if the direction is correct after installation. The correct
direction of installation is that the arrowhead on the safety valve should
point to the water heater.
Please connect the drain hose to the safety valve. Connect one end of the
hose to the safety valve vent and the other end to the sewage drain. The
hose can be cut short or extended as necessary. The hose shall be installed
as inclined downward.
This product should work with the safety valve whose rated pressure is
0.75Mpa.
Hot
water
Safety valve
outlet
Cold water inlet
Shower nozzle