Specifications; Wiring Diagram - FMI MF42IPR Owner's Operation And Installation Manual

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

MF42INR, MF42INV, MF48INR,
MF48INV, VFGT30NR,VFGT30NV,
VFGT36NR, VFGT36NV, VFGT24NR
AND VFGT24NV
• Rating (Variable): 29,000/40,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 3.4" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
WIRING DIAGRAM (REMOTE READY MODELS)
f i r e - p a r t s . c o m
To
Thermopile
WIRING DIAGRAM (VARIABLE CONTROL MODELS)
Note: For proper operation of remote control, wires from thermopile to control receiver must
be connected exactly as shown.
125568-01D

SPECIFICATIONS

Black Connectors
Red
www.fmiproducts.com
MF42IPR, MF42IPV, MF48IPR,
MF48IPV, VFGT30PR, VFGT30PV,
VFGT36PR, VFGT36PV, VFGT24PR
AND VFGT24PV
• Rating (Variable): 29,000/40,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 7.9" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
*For purpose of input adjustment
To OFF Terminal
on Switch
To AUTO Terminal
on Switch
White
To Thermopile
Receiver
31