Specifications; Service Hints; Technical Service - FMI HDL18NRA Owner's Operation And Installation Manual

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

HDL18PRA
• Rating: 25,000/36,000 Btu/hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 14" w.c., Minimum - 11" w.c.
HDL24PRA
• Rating: 25,000/36,000 Btu/hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" w.c.
• Inlet Supply Pressure (inches of water):
Maximum - 14" w.c., Minimum - 11" w.c.

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
f i r e - p a r t s . c o m
• for propane/LP units, propane/LP gas sup-
ply may be low
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural
gas supplier.
125002-01D

SPECIFICATIONS

HDL18NRA
• Rating: 25,000/36,000 Btu/hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" w.c.
• Inlet Supply Pressure (inches of water):
HDL24NRA
• Rating: 25,000/36,000 Btu/hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" w.c.
• Inlet Supply Pressure (inches of water):
You may have further questions about
installation, operation or troubleshooting.
If so, contact FMI PRODUCTS, LLC at
1-866-328-4537. When calling please have
your model and serial numbers of your
heater ready.
You can also visit our web site at
www.fmiproducts.com.
www.fmiproducts.com
Maximum - 10.5" w.c., Minimum - 5" w.c.
Maximum - 10.5" w.c., Minimum - 5" w.c.

TECHNICAL SERVICE

23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdl18praHdl24nraHdl24pra

Table of Contents