Specifications; Technical Service; Service Hints; Replacement Parts - FMI HL18NA Owner's Operation And Installation Manual

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

Models HL18PA and VSB18PB
• Rating (Variable): 16,000/23,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 14" W.C., Minimum 11"* W.C.
• Shipping Weight: 27 lbs.
Models HL18NA and VSB18NB
• Rating (Variable): 17,000/24,000 Btu/Hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum 5"* W.C.
• Shipping Weight: 27 lbs.
*For the purpose of input adjustment.

TECHNICAL SERVICE

You may have further questions about installa-
f i r e - p a r t s . c o m
tion, operation or troubleshooting. If so, contact
FMI PRODUCTS, LLC at 1-866-328-4537.
When calling please have your model and
serial numbers of your heater ready.
You can also visit our web site at
www.fmiproducts.com.
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Contact authorized dealers of this product. If
they can't supply original replacement part(s),
call FMI PRODUCTS, LLC at 1-866-328-
4537.
24

SPECIFICATIONS

REPLACEMENT PARTS

www.fmiproducts.com
Models HL24PA and VSB24PB
• Rating (Variable): 16,000/26,000 Btu/Hr
• Gas Type: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 14" W.C., Minimum 11"* W.C.
• Shipping Weight: 27 lbs.
Models HL24NA and and VSB24NB
• Rating (Variable): 17,000/26,000 Btu/Hr
• Gas Type: Natural
• Ignition: Piezo
• Manifold Pressure: 3.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum 5"* W.C.
• Shipping Weight: 27 lbs.
*For the purpose of input adjustment.

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If
so, contact your local natural or propane/LP
gas supplier.
When calling, have ready:
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural
gas)
• purchase date
Usually, we will ask you to return the part to
the factory.
125006-01A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hl18paHl24naHl24paVsb18nbVsb18pbVsb24nb ... Show all

Table of Contents