9 Disassembly and assembly / 9.9 Dismantling the insulation (≤ A175-L)
9.9
Dismantling the insulation (≤ A175-L)
NOTICE
Dry cleaning
The dry cleaning does not have to be removed to dismantle the insulation.
Fig. 42: Removing the insulation (A175-L and smaller).
1. Loosen and remove screws of insulation jackets (51200) from gas outlet casing (61001).
2. Loosen and remove all connecting plates of insulation jackets.
3. Remove insulation jackets.
4. Detach flange connection between gas inlet casing (51001) and bellows.