Appendix A - Specifications

A
PPENDIX
Power
HDSL2 Span Voltage
Line or Local Power Consumption
Electrical Protection
Environmental
Operating Temperature
Operating Humidity
Physical
Height
Width
Depth
Weight
Mounting
HDSL2
Line Rate
Transmission
Media
Output
Line Impedance
Maximum Loop Attenuation
Start-up Time
DS1
Line Impedance
Line Rate
Line Format
Frame Format
Pulse Output
Input Level
System
One-way DS1 Delay
Wander (Looped)
Wideband Jitter (Looped)
Narrowband Jitter (Looped)
34
A - S
PECIFICATIONS
-180 Vdc
5 W
Secondary surge and power cross-protection on all DS1 and HDSL2 ports.
-40 °F to +149 °F (-40 °C to +65 °C)
5% to 95% (non-condensing)
5.56 in. (14.12 cm)
0.69 in. (1.75 cm)
5.87 in. (14.91 cm)
6.4 oz. (0.18 kg)
400 or 200 mechanics
1.552 Mbps Overlapped Pulse Amplitude Modulation Transmission with Interlocking
Spectra (OPTIS)
Full duplex
One non-loaded, copper, two-wire cable pair
+16.5 dBm ±0.5 dB at 135 Ω (0-350 kHz) at remote side;
+16.8 dBm ±0.5 dB at 135 Ω (0-450 kHz) at CO side
135 Ω
35 dB at 196 kHz, 135 Ω
30 sec. (typical), 1 min. (maximum) per span
100 Ω
1.544 Mbps ±200 bps
Alternate Mark Inversion (AMI) or Bipolar with 8-Zero Substitution (B8ZS)
Extended SuperFrame (ESF), SuperFrame (SF), or Unframed (UNFR)
0 dB, -7.5 dB, -15 dB
0 to -33 dB
<400 µs per span
Meets MTIE T1.101 requirements
0.2 UI maximum
0.1 UI maximum
March 12, 2001
LTPH-TP-1047-01, Issue 1
H2TU-R-402 List 5E