Using The System Event Log To Track Events; System Event Log; H2Tu-R Hdsl2 Alarm Descriptions - ADC HiGain H2TU-R-402 List 5E Technical Practice

Table of Contents

Advertisement

LTPH-TP-1047-01, Issue 1
Screen Alarm
Front-Panel Alarm Description
LOSW
LOSW
MAL
MAL
LA
LA
HBER
HBER
U
S
SING THE
YSTEM
To view a running log of system events, press
time of the 100 most recent events (most recent displayed first) and provides a description of each event. See
Table 9 on page 24
for a complete list of event log messages.
N
P
Press
or
to page through the event log.
T
Press
to return to the top of the log.
L
Press
to clear the event log.
Monitor
Performance
------------------------------------------------------------------------------
#
Origin
1
System
2
System
3
System
4
System
5
System
6
System
7
H2TU-C
8
H2TU-C
9
H2TU-R
10
H2TU-R
11
System
12
H2TU-C
13
H2TU-C
14
- EMPTY -
15
- EMPTY -
Press: (N)ext Page, (P)revious Page, (T)op of Log, C(l)ear Log
ID: xxxx--xxxx—-xxxx--xxxx
H2TU-R-402 List 5E
Table 8. H2TU-R HDSL2 Alarm Descriptions
Loss of Sync Word—The HDSL2 loop has lost synchronization.
Margin—The margin on the HDSL2 loop has dropped below the minimum threshold
value set for the system.
Loop Attenuation—The attenuation on the HDSL2 loop has exceeded the maximum value
set for the HDSL2 loop attenuation threshold.
Block Error Rate—The HDSL2 BER has exceeded the set threshold limits of 10
E
L
VENT
OG TO
E
to select the Event Log. The Event Log displays the date and
Event Log
Config
Inventory
System Event Log (Page 1 of 7)
Date and Time
01/19/01
12:25:00
01/20/01
12:25:00
01/21/01
12:25:00
01/22/01
12:25:00
01/23/01
00:13:32
01/24/01
00:13:27
01/25/01
00:13:27
01/26/01
00:11:16
01/27/01
00:10:43
01/28/01
00:10:30
01/29/01
00:04:11
01/30/01
00:00:40
01/31/01
00:00:02
02/01/2001 12:30:01
Figure 21. System Event Log
March 12, 2001
Monitoring System Activity and Performance
T
E
RACK
VENTS
Report
Rlogon
Entry
DS1 Alarm Register reset
HDSL2 Alarm Register Reset
DS1 Performance Register Reset
HDSL2 Performance Register Reset
Time set 12:25:00
Date set 02/01/01
NLOC: Loop-down
NLOC: Loop-up
DS1 LOS Alarm: End
DS1 LOS Alarm: Begin
DS1C: AUTO to AMI
HDSL2 LOSW Alarm: End
HDSL2 LOSW Alarm: Begin
H2TU-C
System:
-6
- 7
or 10
.
Help
OK___
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

150-2450-55