Mitsubishi Electric MUZ-DW25VF-E1 Service Manual page 41

Table of Contents

Advertisement

J Check of power supply
Disconnect the connector between the
compressor and the power module
(IC700). Turn ON power supply and
press the emergency operation switch.
Does the upper OPERATION
INDICATOR lamp on the indoor unit
light up?
Yes
Is there bus-bar voltage 260 - 370 V
DC between DB61 (+) and DB61 (–)
on the inverter P.C. board? (Refer
to 12-6.1.)
No
Check the electric parts in main circuit.
OBH906A
Rectify indoor/outdoor
connecting wire.
Yes
Is there voltage 230 V AC
between the indoor terminal
No
block S1 and S2?
Does LED on the inverter P.C.
board light up or blink?
Yes
(Refer to 12-6.1.)
Yes
If lights up, OK.
If blinks, refer to 12-3.
41
Replace the indoor
electronic control P.C.
No
board.
Replace the inverter
No
P.C. board.
260 - 370 V DC
DB61
Inverter P.C. board
(Solder side)

Advertisement

Table of Contents
loading