APPLIANCE DESCRIPTION

The CODEX GT appliances by ICI Caldaie S.p.A. are condensing Boilers made in AISI 316 Ti STAINLESS steel with three-pass furnace
for the production of hot water at a maximum temperature of 110°C. They are provided with pre-mixed, modulating burner for
gaseous fuels with cylindrical, heat radiating body and low NOx emissions.
They are equipped with two-stage progressive or premixed modulating gas burner, with cylindrical combustion head and
radiation with low emissions of NOx. The Nominal Efficiency of the CODEX GT reaches 108% (REF. NCV) e  (in compliance
with Directive 92/42/EEC).
The control panel suitable for the Boiler can be indifferently installed either on the right side or on the left side of the appliance.
Some of the main characteristics of the Boiler are listed below:
– chassis made of steel vertical profile structure, complete with base
– large-size cylindrical furnace made of TIG welded AISI 316 Ti stainless steel, able to withstand condensate attacks
– The CODEX GT appliances by ICI Caldaie S.p.A. are condensing Boilers made in AISI 316 Ti STAINLESS steel with three-pass
furnace for the production of hot water at a maximum temperature of 110°C. They are provided with pre-mixed, modulating
burner for gaseous fuels with cylindrical, heat radiating body and low NOx emissions
– welding performed with TIG procedure , a method which does not require any material to be added, and thus ensures that the
main mechanical characteristics of stainless steel are preserved, as well as its capability to resist acid condensate corrosion
– flow flange fitting and two system return fittings , to distinguish the Boiler inlet and ensure the minimum possible temperature
at the lowest point, thus getting the most out of condensate benefits, even in the presence of medium-high temperature
return
– smokebox which can collect the produced condensate, which is then drained through a trap to be connected to the
neutraliser (where provided) and thus to the domestic hot water drain line
– very high water content and low thermal load
– "hot" surfaces insulated with extra-thick glass wool mats, protected by painted steel panels which are easy to disassemble
– front door with reversible opening , made of steel sheet, thermally insulated with ceramic fibre
– radiant premixed modulating burner , which can provide any power output between the min and the max, according to the
instant load request; it allows maximum acoustic comfort and low polluting emissions.
STRUCTURE
7
8
1
2
3
4
5
6
1
Door opening handle
2
Upper door
3
Burner support flange
4
Burner
5
Hinges
6
Lower door
7
Flame inspection window
6
Cooke Industries - Phone: +64 9 579 2185
9
10
8
Combustion chamber pressure test
connection
9
Control panel (accessory)
10
Insulating casing
11
Inspection fitting
12
Smokebox
13
Medium-temperature return
Email: sales@cookeindustries.co.nz
20
11
12
13
14 15
14
Condensate drain
15
Available fitting
16
Boiler drain
17
Available fitting
18
Low-temperature return
19
System flow
20
Flue gas drain fitting
Web: www.cookeindustries.co.nz
19
16 17
18
General information

Advertisement

Table of Contents
loading