Wall mount shower only faucet

Advertisement

G1/2˝
58~68
122
INSTALLATION
1
2
2
3
4
1250178-2A-A
Ø116
G1/2˝
G1/2˝
49
G1/2˝
60
How to Install the Faucet
To perform installation, installer must provide G1/2˝
female supply fittings(1), spaced 150mm apart and
horizontally. The supply fittings should be vertical and
not beyond the finished wall. Hot supply pipe must be
located on the left.
Install the two offset connectors(2) into the hot and
cold supply pipes. Use appropriate thread sealants or
thread tape on pipe threads.
Adjust the center-to-center distance between the
connectors to 150mm and horizontally. They should
extend 31~41mm beyond the finished wall. Install the
escutcheons(3) onto the connectors until they are
against the finished wall.
5
Put the washers(4) into the nuts(5), thread the nuts to
connectors. Tighten the nuts with strap wrench or soft
cloth between product and regular wrench.
75522T-4
13
14
INSTALLATION CHECKOUT
CLEANING INSTRUCTIONS
All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft
cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc, which could adversely
affect the finish and are not recommended for cleaning.
Do not use abrasive cleaners or solvents on Kohler faucets and fittings.
2
1250178-2A-A
Put the washer(8) into the end A of the hose(9), and
connect to the faucet outlet(10).
12
Put the check valve(11) into the handshower(12) inlet
as shown if needed. Put the washer(8) into the end B
11
of the hose, and connect to the handshower.
8
10
B
8
A
9
How to Install the Bracket
Determine a suitable location on the finished wall to
install the bracket.
Mark bracket base mounting hole locations on the wall
according to the dimension. Drill two holes on the
15
finished wall, the holes should match the anchors(15).
Install the anchors. Tighten screws(16) to secure
bracket base(13) to the finished wall. Put the
bracket(14) onto the bracket base and lock by
stopper. Hang the handshower on the shower bracket.
16
Ensure that all coupling nuts are tight. Ensure that the
lever handle is in the off position.
12
Turn on the main water supply and drain, and check
for leaks. Repair as needed.
Remove the handshower(12), remove aerator(17) by
key(18). Run hot and cold water through faucet for
about one minute to remove any debris. Check for
17
leaks. Repair as needed. Remove any debris from the
18
aerator. Shut off the faucet. Reinstall the aerator.