KPS TP5000HY User Manual

KPS TP5000HY User Manual

True rms electrical tester
Hide thumbs Also See for TP5000HY:

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for KPS TP5000HY

  • Page 2: Maintenance

    TP5000HY WARNING • If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. • Always use proper terminals, switch position, and range for measurements. • To reduce the risk of fire or electric shock, do not use this product around explosive gas or in damp locations.
  • Page 3 TP5000HY Voltage / Continuity / Single Pole Mode Voltage Measurement 1000 12 - 2 0 0 A C A T .I 6 0 0 V C A T .I 1 0 0 0 12 - indicates measured voltage is high than ELV limit (50VAC and/or 120VDC).
  • Page 4 TP5000HY Single Pole Phase Check Warning • Single Pole Check is available for both test leads. Remove one of test leads before performing check. • Do not check if voltage appears by Single Pole Phase Check. Measure voltage with two pole to get a reliable result.
  • Page 5: Using The Function

    TP5000HY Using the Function HOLD Enable/Disable ELV Warning Voice Turn the meter OFF Press Ω/A button and “HOLD” button at the same time. Torch Self-Diagnostic Test Warning Do not use the tester when abnormality is found in self-diagnostic test.
  • Page 6: Function Button

    TP5000HY Function Button Battery Replacement Warning • To avoid false readings that can lead to electric shock and injury, replace the battery as soon as low battery indicator • Remove test lead from Meter before opening the battery door or Meter case.
  • Page 7: Specifications

    TP5000HY Test lead assembly Warning Do not assemble test lead at the back of the meter while measuring current. Storage For most application except For 19mm power socket ampere measurement. Specifications 1-1 General Specifications Display Count : 10000 counts. Overrange Display : ”OL” or “-OL”...
  • Page 8: Electrical Specifications

    TP5000HY 1-3 Electrical Specifications Accuracy is given as ± (% of reading + counts of least significant digit) at 23°C ± 5°C, with relative humidity Less than 80% R.H., and is specified for 1 year after calibration. Condition of Auto Power On : •...
  • Page 9 TP5000HY • Resistor Range Resolution Accuracy 9999Ω 1Ω ±(1.5% + 5D) 50.00kΩ 0.01kΩ Output Voltage : about 0.5V Overload Protection : AC/DC 1000V • Continuity Continuity : The built-in buzzer sounds in the case of measuring resistance less than 1.8kΩ and may be up to 2.7kΩ. LED RX shows at the same time.