Anomaly Warning; Remote Signalling Alarm; Before Start Up - omi DD36 Operator's Manual

Direct expansion compressed air dryers
Table of Contents

Advertisement

3.1.3 DISPLAY INDICATIONS
The controller is capable of recognizing certain types of anomalies in the drying circuit. In such cases, a message will blink on the
display, alternated to the current dew point value.
MESSAGE
(BLINKING)
HtA
Ht2
Interruption or short circuit on the
PF1
ESA
The automatic Energy saving
mode activated due to low load
ES2
ASt
Activated after repeated alarms
Note: PF1 has priority on all other messages.
3.1.4 REMOTE SIGNALING ALARM (OPTIONAL)
Alarm Output relays electric features:
Max. 250VAC / 3A – AC 15 (Amp. Inductive)
The activation of the above function is at the User's discretion. The User will purchase all necessary installation material.
Any operation which needs access to the dryer must be carried out by qualified personnel.

3.2 BEFORE START UP

Before starting the machine, make sure that all operating parameters correspond to the nominal data.
The dryer is supplied already tested and preset for normal operation, and it doesn't require any calibration. Nevertheless,
it's necessary to check the operating performances during the first working hours.
Cod. 710.0167.01.00 Rev02 – 10.2019
CAUSE
High dew point value
(delayed alarm)
Very high dew point value
(immediate alarm)
PTC probe input line
The dryer control board is equipped with a dry contact for a remote alarm signal. This is normally open
contact: when an alarm is detected, this contact is closed.
Proceed as follows to activate a remote alarm output:
1. The User must review the diagram below.
2. Disconnect the dryer from electrical power supply, remove cover and left side panel.
3. Connect the alarm circuit to the terminal blocks (See PIC.2).
4.
Replace cover, left side panel and reconnect power.
© Copyright 2019 OMI Srl - All rights reserved
OUTPUTS
Alarm output ON
Refrig. Compressor output OFF
Fan output ON
Drain cycle standard
Alarm output ON
Refrig. Compressor output OFF
Fan output OFF
Drain cycle standard
Alarm output OFF
Refrig. Compressor output OFF
Fan output OFF
Drain cycle standard
Alarm output ON
Refrig. Compressor output OFF
Fan output ON
Drain cycle standard
PIC.2
ACTIONS
Resettable by switching off the
dryer.
If problem persists call your local
OMI distributor.
Resettable by switching off the
dryer. May require replacing the
faulty probe.
If problem persists call your local
OMI distributor.
No action necessary.
Automatic Reset
Call your local OMI distributor.