DIRECT EXPANSION COMPRESSED AIR DRYERS
Operators Manual
ED HP45
88 – 108 – 180
225 – 270 – 360
480 – 660 – 990 – 1200
Cod. 710.0201.01.00 Rev.01 – 05.2022
1 - 11
© Copyright 2022 OMI Srl - All rights reserved

Advertisement

Table of Contents
loading

Summary of Contents for omi ED88 HP45

  • Page 1 DIRECT EXPANSION COMPRESSED AIR DRYERS Operators Manual ED HP45 88 – 108 – 180 225 – 270 – 360 480 – 660 – 990 – 1200 Cod. 710.0201.01.00 Rev.01 – 05.2022 1 - 11 © Copyright 2022 OMI Srl - All rights reserved...
  • Page 2 Cod. 710.0201.01.00 Rev.01 – 05.2022 1 - 11 © Copyright 2022 OMI Srl - All rights reserved...
  • Page 3: Table Of Contents

    ATTACHMENTS TO THIS MANUAL A) Refrigerant circuit B) Electric circuit diagram C) Technical data sheet D) Correction factors E) Dryer dimensions F) Basic spare parts Cod. 710.0201.01.00 Rev.01 – 05.2022 2 - 11 © Copyright 2022 OMI Srl - All rights reserved...
  • Page 4 Cod. 710.0201.01.00 Rev.01 – 05.2022 3 - 11 © Copyright 2022 OMI Srl - All rights reserved...
  • Page 5 Please note that, when necessary, the use of original spare parts will ensure efficiency and long duration to your dryer. Due to the continuous technological evolution,OMI reserves the right to modify the specifications contained in this manual without giving previous notice.
  • Page 6: General Information

    1. GENERAL INFORMATION 1.1 FUNCTIONAL DESCRIPTION OMI refrigerated air dryers remove moisture from compressed air. Moisture is detrimental to pneumatically operated appliances, controls, instruments, machinery and tools. Compressed air enters the patented aluminum heat exchanger where it is cooled down to the dew point temperature in two different stages: In the first air/air sector compressed inlet air is cooled thanks to the colder compressed air coming out counterflow from the condensate separator.
  • Page 7: Acceptance And Transportation

    2.1 ACCEPTANCE AND HANDLING Upon receiving your OMI air dryer, please inspect the unit closely. If rough handling is detected, please note it on your delivery receipt, especially if the dryer will not be uncrated immediately. Then obtain the freight carrier's signed agreement to any noted damages: this is a precondition for any insurance claims by the customer.
  • Page 8: Installation

    In models ED480-1200 HP45, in order to adjust the greater dryer’s cooling capacity, a hot gas by-pass valve cooperates with the variable speed system. Cod. 710.0201.01.00 Rev.01 – 05.2022 4 - 11 © Copyright 2022 OMI Srl - All rights reserved...
  • Page 9: Control Panel

    NOTE: when the controller is in the OFF position, some parts of the dryer may still be energized. Therefore, for safety purposes, disconnect the electrical power before performing any operation on the machine. Cod. 710.0201.01.00 Rev.01 – 05.2022 5 - 11 © Copyright 2022 OMI Srl - All rights reserved...
  • Page 10: Condensate Discharge Parameters Programming

    Refrig. Compressor output OFF Activated after repeated alarms Call your localOMI distributor. Fan output ON Drain cycle standard Note: PF1 has priority on all other messages. Cod. 710.0201.01.00 Rev.01 – 05.2022 6 - 11 © Copyright 2022 OMI Srl - All rights reserved...
  • Page 11: Remote Signalling Alarm

    Before disconnecting the dryer from electrical power supply, use ON/OFF switch to stop the dryer. Otherwise wait 10 minutes before switching the dryer on again, in order to allow freon pressure to rebalance. Cod. 710.0201.01.00 Rev.01 – 05.2022 7 - 11 © Copyright 2022 OMI Srl - All rights reserved...
  • Page 12: Maintenance

    Troubleshooting and eventual control and/or maintenance operations must be performed by qualified personnel. For maintaining the refrigerating circuit of the machine, contact a refrigeration engineer. Cod. 710.0201.01.00 Rev.01 – 05.2022 8 - 11 © Copyright 2022 OMI Srl - All rights reserved...
  • Page 13 Check the probe; if the trouble persists, replace it. improperly or faulty. Series of alarms very close to each other. Call your localOMI distributor. Cod. 710.0201.01.00 Rev.01 – 05.2022 9 - 11 © Copyright 2022 OMI Srl - All rights reserved...
  • Page 14 No parts of the system are electrically powered. When it is necessary: Filter mesh  Clean the mesh filter of the condensate drainage system.  Clean the filter mesh. Cod. 710.0201.01.00 Rev.01 – 05.2022 10 - 11 © Copyright 2022 OMI Srl - All rights reserved...
  • Page 15: Decommissioning

    Send the dryer to an approved waste disposal company in accordance with current environmental protection legislation. The other materials/waste constituents must be treated in line with the provisions of the valid legislation. Cod. 710.0201.01.00 Rev.01 – 05.2022 11 - 11 © Copyright 2022 OMI Srl - All rights reserved...
  • Page 16: Safety Informations

    Such devices will have to be carried out according to the applicable National Norms and to the limits mentioned in this Manual. Ozone layer deterioration: The adoption of HFC freon reduce to the minimum ozone layer deterioration and greenhouse effect. Cod. 710.0201.01.00 Rev.01 – 05.2022 12 - 11 © Copyright 2022 OMI Srl - All rights reserved...