7. The analog voltage interface

The analog interface on the main connector produces a linear voltage of between 0.00 V and 2.56 V that is proportional to the
closest measured distance. A distance reading of zero meters always produces a 0 V output.
Setting
@ 1.00 m
@ 0.50 m
5. Analog port
@ 0.25 m
update rate
@ 0.03 m
@Filter
6: Analog maximum range
The "5: Analog port update rate" setting allows the output rate of the analog port to be set to any value within the limits imposed by
the snapshot resolution. Values will be rounded in order to give whole number divisors of 3052 and limited automatically if they are
too high for the resolution selected.
The "6: Analog maximum range" selection changes the value in meters that equates to 2.56 V. This can be either: 128 m, 64 m,
32 m, 16 m or 8m depending upon the requirements of the application.
SF33 Multi-beam sensor - Product Manual - Revision 1
Product manual
Figure 8 :: Analog voltage connections
Values
10 ... 3052 / sec
Sets the rate at which the analog port and the alarm signal are
updated with distance readings.
10 ... 1526 / sec
The actual value may be lower than the entered value depending
10 ... 763 / sec
on the setting "2: Snapshot resolution".
10 ... 95 / sec
Only whole number fractions of 3052 will give an exact match
between the entered and actual values.
10 ... 95 / sec
128 m <-> 64 m <->
Selects the maximum distance that produces 2.56 V on the analog
32 <->
port. This value changes the scale of the analog output.
16 m <-> 8 m
11