Fault
Motor does not turn.
Motor does not turn, clean-
ing head does not turn
Cleaning head turns too
abruptly
Uneven cleaning jet

Accessories

Description
Maintenance unit for com-
pressed air (only for com-
pressed air drive)
Hole cone in PE design
Locking screw (for 1 noz-
zle operation)
Compressed air filter with
automatic condensate
drain (only for compressed
air drive)
Compressed air hose
(sold by the meter)
Exhaust air silencer with
oil separator

CE declaration

We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements of the
EU Directives, both in its basic design and
construction as well as in the version put
into circulation by us. This declaration shall
cease to be valid if the machine is modified
without our prior approval.
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
CEO
Head of Approbation
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
D - 71364 Winnenden
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
18
English
Possible cause
There is no voltage at the motor.
Thermal protection switch in the
coil has triggered.
Error current protective switch was
triggered.
No compressed air present or
pressure too low.
Compressed air supply line kinked. Check compressed air hoses.
Mechanical defect on:
– Coupling parts
– Drive shaft
– Gears
Cleaning head touches container
wall.
Worn drive discs cause increased
bevel play.
Destroyed gears on bevel wheels. Replace bevel wheels.
Spray nozzles clogged.
Spray nozzles damaged.
5.957-453
Order No.
Product:
Type:
6.610-020
Relevant EU Directives
98/37/EC (to 28.12.2009)
2006/42/EC (from 29.12.2009)
2006/95/EC
5.132-016
2004/108/EC
5.411-061
Applied harmonized standards
EN 55014–1: 2006
6.414-154
EN 55014–2: 1997 + A1: 2001
EN 60204–1
EN 61000–3–2: 2006
EN 61000–3–3: 1995 + A1: 2001 + A2:
2005
6.388-192
on request
5.957-454
Product:
Type:
Relevant EU Directives
98/37/EC (to 28.12.2009)
2006/42/EC (from 29.12.2009)
94/9/EC
Applied harmonized standards
EN ISO 12100–1
EN ISO 12100–2
EN 1127-1: 1997
EN 13463-1: 2002
EN 13463-5: 2003
Applied national standards
-
ID no. of notified body
0123
TÜV SÜD
Ridlerstr. 65
80339 München
Test report no.
Ex5 0307 10088 097
Marking
II 1/2 G c T4
Troubleshooting
Remedy
Check fuse and cables.
Fix cause for overload.
Remove cause and reset error current protective
switch.
Check compressed air supply.
Check parts and replace defective parts.
Change position of cleaning head and make
sure it can run smoothly.
Replace drive discs.
Clean spray nozzles.
Replace spray nozzles.
HKF 50 E
Internal cleaner
HKF 50 E
HKF 50 P
Internal cleaner
HKF 50 P
of whom
Electricians
Electricians
Electricians
Operator
Operator
Customer Service
Operator
Customer Service
Customer Service
Operator
Operator
II 1/3 D c 120 °C

Warranty

The warranty terms published by our com-
petent sales company are applicable in
each country. We will repair potential fail-
ures of the appliance within the warranty
period free of charge, provided that such
failure is caused by faulty material or de-
fects in fabrication.
In the event of a warranty claim please con-
tact your dealer or the nearest authorized
Customer Service centre. Please submit
the appliance, including all accessories,
and the proof of purchase.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hkf 50 p3.631-0093.631-008

Table of Contents