15
9.4
After cleaning, connect the cables to the
batteries, and tighten them to the torque
specifications listed on the battery, gener-
ally 10 to 15 lbf·ft (14 to 20 N·m).
9.5
Spray each connection with dielectric red
enamel and coat the battery terminals
with dielectric grease; see
Approved Dielectric Protectants
Protectant Material
Dielectric Grease
Lubriplate FLP DS–ES
3M 1602 IVI-Spray Sealer; order
Dielectric Red Enamel
from the PDC
Spray-On Application
Spray-On B–6–665
Gyptal 1201EW-Low VOC, Red;
Dielectric Red Enamel
order at www.glyptal.com or
Brush-On Application
1-800-GLP-1201
Table 1, Approved Dielectric Protectants
10. Check the terminals on the battery shut-off
switch and the magnetic switch. Make sure the
terminal connections are clean and tight. Coat
the terminal connections with dielectric red
enamel after cleaning.
15/2
Table
1.
Approved Brand
Alternators and Starters
Century Class Trucks Maintenance Manual, January 2006