Summary of Contents for Allmand Nite Lite V Series
Page 1
● Voltage Regulator- (650446) ● 15 Amp switch (lights)- 106781 ● SLS Module- 108053 Nite Lite V Series Parts: ● 35 Amp double pole breaker- (350354) ● 15 Amp SPST breaker switch/ light- (330458) ● 20 Amp GFCI receptacle/outlet- (330499) ●...
Page 2
Nite Lite V Series SERIAL NUMBER 39-000001 AND UP Note: S LS is made to save the capacitors and generator. The module ensures the 120 volts are present before the lights are turned on. Primary job is to save the relays. Unit runs for 45 seconds to 1 minute and shuts down: ●...
Page 3
Nite Lite V Series SERIAL NUMBER 39-000001 AND UP ● ● If the capacitor is good and the problem persists then the generator needs to be replaced or flashed. S ee generator manufactures manual for troubleshooting. ● If there is sufficient power at both GFCI and main breaker then the A/C power circuit will have to get tested.
Page 4
Nite Lite V Series SERIAL NUMBER 39-000001 AND UP ● ● thein ( E xample B ) Multiple lights will not Illuminate:...
Page 5
Nite Lite V Series SERIAL NUMBER 39-000001 AND UP ● If you are having an issue with all four lights or multiple ones not illuminating, ensure there is sufficient power from the generator, main breaker, & light switches to your ballast (120/240 v) ●...
Page 6
How to test Capacitors for lights and generators: Important: ● Please contact Allmand Brothers to obtain the correct capacitor & rating. Never use a smaller Uf (Microfarad) or different voltage rating for Generators. ● Disconnect Both capacitor leads for the light capacitors.
Page 7
Nite Lite V Series SERIAL NUMBER 39-000001 AND UP ● Example “A” WARNING: Dangerous voltage and/or current may be present when a voltage test is being conducted. To reduce the risk of serious injury or death from electrical shock, if you are not trained to safely work with high voltage, do not attempt any of these procedures.
Page 8
GFCI receptacle itself, or the wiring in between any of these. ● Note: M any Allmand light towers designed for use outside of North America operate at 230 volts/50 Hz. Testing is done the same way following the above instructions.
Page 9
Nite Lite V Series SERIAL NUMBER 39-000001 AND UP Testing Generator output at the main circuit breaker: ● If testing the Generator output at the GFCI receptacle (Example “L” above) shows zero or low voltage, or is conclusive, it will then be necessary to test the generator voltage at the main circuit breaker.
Page 10
Nite Lite V Series SERIAL NUMBER 39-000001 AND UP ● Example L:...
Page 11
(See Example “D” and Example “B”). The meter reading should indicate 120 volts + 10%. If the reading of 120 Volts +10% is not measured at each terminal, the main breaker is faulty and must be replaced. Contact Allmand Parts Department (308-995-4495) for the correct replacement circuit breaker.
Page 12
Nite Lite V Series SERIAL NUMBER 39-000001 AND UP ● Example A: ● Example N: WARNING: Dangerous voltage and/or current may be present when a voltage test is being conducted. To reduce risk of serious injury or death from electrical shock, if you are not trained to safely work with high voltage, do not attempt any of these procedures.
Page 13
Nite Lite V Series SERIAL NUMBER 39-000001 AND UP Testing Engine speed at the GFCI receptacle: ● The operating speed of the engine may be tested by using a multimeter with the scale set to read Hertz (Hz) NOTE: N ot all multimeters have Hertz scales.
Page 14
Nite Lite V Series SERIAL NUMBER 39-000001 AND UP ● Note: Many Allmand Light towers designed for use outside of North America operate at 230 volts + 10%/50Hz. Engines on these models must be set for 52.0 Hz at no load per the above instructions. If you are unsure which voltage your light tower is designed to produce contact a qualified electrician for assistance.
Page 15
Nite Lite V Series SERIAL NUMBER 39-000001 AND UP ● into terminal “R”. From terminal “R” the connection must be ran into Engine harness #5 pin. Ensure contact is being made. Example “R”- see next page for wiring instructions. ●...
Page 16
Nite Lite V Series SERIAL NUMBER 39-000001 AND UP FUEL 108430 FILTER KIT (ALL FUEL) 108963 KUBOTA D905,D1005, & D1105 8KW 650290 920743 FUEL 920745 FILTER KIT (ALL FUEL) 108962 PERKINS 403F-11 8KW 650290 113867 FUEL 113874 FILTER KIT (ALL FUEL) CAT C1.1 8KW &...
Page 17
SERIAL NUMBER 39-000001 AND UP *Check engine operators manual for specific recommended lubricants. *Additional warranty information & claim forms can be obtained on Allmand.com. *Please contact Allmand Tech line for additional help and troubleshooting @ (308) 995-3431 / Parts (800) 562-1373.
Need help?
Do you have a question about the Nite Lite V Series and is the answer not in the manual?
Questions and answers