SAFETY PRECAUTION
The machine is adaptive in following situation
1. Applicable ambient temperature range:
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T3.15A /250VAC.
4. The wiring method should be in line with the local wiring standard.
5. The power cable and connecting cable are self-provided.
The power cable should beH07RN-F 5G 2.5mm2 (for 36,42 series, 28 series (380-400V,
3N~, 50Hz)) or H07RN-F 3G 4.0mm2 (for 24,28,36 series (1PH, 220-230V~, 50Hz)) .
The connecting cable parameter is different by different type, please select properly
spelification from below:
1)H05RN-F 6x1.5mm2
2)H05RN-F 3G1.5mm2+H05RN-F 1x0.75mm2
All the cables shall have got the European authentication certificate. During installa-
tion, when the connecting cables break off, it must be assured that the grouding wire is
the last one to be broken off.
6. The breaker of the air conditioner should be all-pole switch; and the distance between its
two contacts should be no less 3mm.
7. The indoor unit installation height is at least 2.5m.
Maximum:
D.B / W.B
Minimum:
D.B / W.B
Maximum:
D.B / W.B
Minimum:
D.B
Maximum:
D.B
Minimum:
D.B
Maximum:
D.B / W.B
Minimum:
D.B / W.B
D.B / W.B
5
32
/ 23
18
/ 14
43
/ 26
15
27
15
24
/ 18
-7
/ -8