Cautions ------------------------------------------ Safety Precautions ----------------------------- AD25S2PS1FA Installaiton Manual For Wire Controller --- Heating Mode ------------------------------------ AD35S2PS1FA Troubleshooting --------------------------------- Precaution for Installation ------------------- Is The Unit Installed Correctly --------------- Installation Procedure ------------------------- Operation------------------------------------------ AD50S2PS1FA AD71S2PS1FA 0150557264...
Page 3
Read the precautions in this manual This appliance is filled with R32. carefully before operating the unit. Service indicator; Read technical Read the operator's manual manual The installation and service of this product shall be carried out by professional personnel, who have been trainedand certified by national training organizations that areaccredited to teach the relevant national competency standards that may be set in legislation.
Page 4
•A brazed, welded, or mechanical connection shall be made before opening the valves to permit refrigerant to flow between the refrigerating system parts. A vacuum valve shall be provided to evacuate the interconnecting pipe and/or any uncharged refrigerating system part. •The maximum working pressure is 4.3 MPa.
Page 5
China China IMPORTANT INFORMATION REGA- DISPOSAL REQUIREMENTS: RDING THE REFRIGERANT USED Your air conditioning product is marked with this Contains fluorinated greenhouse gases symbol.This means that electrical and electronic covered by the Kyoto Protocol products shall not be mixed with unsorted household waste.Do not try to dismantle the system yourself:the dismantling of the air conditioning system,treatment of the refrigerant,of oil and of...
Cautions Disposal of the old air conditioner Disposal of the packaging of your new air conditioner Safety Instructions and Warnings...
Page 7
Cautions - The installation of pipe-work shall be kept to a minimum. - Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than Amin(2m - Compliance with national gas regulations shall be observed. - Mechanical connections shall be accessible for maintenance purposes.
Page 8
Cautions Checks to electrical devices - Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.
Page 9
Cautions - Become familiar with the equipment and its operation. - Isolate system electrically. - Before attempting the procedure, ensure that: • mechanical handling equipment is available, if required, for handling refrigerant cylinders; • all personal protective equipment is available and being used correctly; •...
Heating Mode "HOT KEEP" function Warming operation "HOT KEEP" is operated in the following cases. Care and Maintenance Points to observe CAUTION Care and Cleaning of the unit Cleaning the air filter Post-Season Care Pre-Season Care CAUTION...
Is The Unit Installed Correctly Installation place Electric work When you change your address or the installation place For inspection and maintenance Installation Procedure Indoor Unit CAUTION Please do not install the unit in places where flammable gases may be leaked The indoor unit shall be installed at locations where cold and hot air could evenly circulated.
Installation Procedure Indoor Unit Selecting the mounting position to install the indoor units After selecting the unit installation location, proceed the following steps: Installation dimension AD25S2PS1FA AD35S2PS1FA AD50S2PS1FA AD71S2PS1FA AD25S2PS1FA AD35S2PS1FA AD50S2PS1FA AD71S2PS1FA 1212 1170 1080 Installation Procedure Air Duct...
Page 21
Installation Procedure Air Duct The sketch map of long duct 1. Installation of air sending duct 2. Installation of air return duct rivet 3.Thermal insulation of duct...
Page 23
Installation Procedure Refrigerant Pipe Open all valves Gas leakage detection Insulation treatment Installation Procedure Drain Pipe CAUTION Requirements For unit without water pump For unit with water pump Pipe and insulation material...
Page 24
Installation Procedure Electrical wiring Hose Drain confirmation WARNING DANGER OF BODILY INJURY OR DEATH Precautions for Electrical wiring Wiring connection The specification of power cable is HO5RN-F3G 4.0mm . The specification of cable between indoor unit to outdoor unit is HO5RN-F4G 2.5mm...
Operation Wi-Fi The system architecture diagram The application environment Smart mobile phone and wireless router are necessary for the appliacation. Wireless router must be able to connect to the Internet. Smart mobile phone requires IOS or Android system: IOS system Android system must support IOS 9.0 or above must support Android 5.0 or above...