Cautions - Haier AB092ACBJA Operation And Installation Manual

Cassette type air conditioner
Table of Contents

Advertisement

Cautions

Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers or any other things into the
inlet/outlet and swing louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following
situation
1. Applicable ambient temperature range:
AB092/122ACBJA AB142/182ACBJA:
DB C
Indoor
WB C
Cooling
DB C
outdoor
WB C
Indoor
DB C
Heating
WB C
outdoor DB C
WB C
AB142/182ACBFA:
DB C
Indoor
WB C
Cooling
DB C
outdoor
WB C
Indoor
DB C
Heating
WB C
outdoor DB C
WB C
2. If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similar qualified person.
3. If the fuse on PC board is broken, please
change it with the type of T3.15A /250VAC.
4. Use copper wire only. The connecting cable
should be H05RN-F 3G(2.5mm
1x 0.75mm
2
. The power cable should be
H05RN-F 3G 2.5mm
2
have got the European authentication certificate.
***************
Rated Maximum Minimum
27
32
18
19
23
14
35
43
-5
24
26
--
20
27
15
14.5
--
--
7
24
-7
6
18
--
Rated Maximum Minimum
27
32
18
19
23
14
35
43
10
24
26
--
20
27
15
14.5
--
--
7
24
-7
6
18
--
2
+H05RN-F
051220*********
.All the cables shall
5. The power cord should be self-provided and
it should have got the Local authentication
certificate.
6. The air breaker should be all-pole switch.
and the distance between it's two
connecters should no less than 3mm.
7. Air conditioner must use special power supply
system (above 20A), and qualified electrician
makes wiring and fixing according to wiring
regulations specified in national standard.
8. In socket, exactly distinguish earth wire with
neutral wire and it is wrong to connect them
together.
9. A leakage breaker must be installed.
10. Connection method is Y-connection .If the
power cord is damaged, it must be replaced
by professional people of manufacturer or its
maintenance department or similar to avoid
dangers.
11. The air breaker and the power switch should
installed the conveniently reachable place for
user.
AB142ACBFA AB182ACBFA:
Attention:
As a result of poor conditions of the electrical
MAINS, shortly voltage drops can appear
when starting the EQUIPMENT. This can
influence other equipment (et.Blinking of a
lamp). If the MAIN-IMPEDANCE Zmax<
0.3970617HM, such disturbance are not
expected. In case of need , you may contact
your local supply authority for further
information.
Other Instructions
1. The waste battery
should
When throw away the waste batteries, please
perform in accordance with the local regulation.
2. The indoor unit installation height is at least
2.5m.certificate.
2
*****
be disposed properly.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ab122acbjaAb142acbfaAb142acbjaAb182acbfaAb182acbja

Table of Contents