Start-Up; Setting System Parameters - Vaillant auroMATIC 560 Operating And Installation Manual

Solar differential control
Table of Contents

Advertisement

Available languages

Available languages

6 Start-up

6
Start-up
6.1

Setting system parameters

A few system parameters have to be set in order for the
system to comply optimally with the respective condi-
tions. These parameters are all together on one operat-
ing level and should only be set by a heating engineer.
You can access this operating level by holding the pro-
gramming button down for approximately three seconds.
Display
Setting by turning the dial
Change the hydraulic plan
Set the flow rate.
When setting the required flow rate, take note
of the units employed by the installed flow
rate limiter!
Reset the solar yield.
The solar yield is set to 0 by turning the dial
to 1.
Reset the operating hours.
The operating hours are set to 0 by turning
the dial to 1.
Set the maximum temperature for Cylinder 1
Table 6.1 System parameters
a
Caution:
The maximum permissible temperature for the
installed cylinder (MAXT 1) must not be exceed-
ed.
20
Then you can call up all the system parameters consecu-
tively by clicking the dial. You can set the desired values
by turning the dial. The set value is saved with a click.
If you press the programming button P, the display
jumps back to the basic display without saving the value.
The following table gives an overview of all system pa-
rameters and their factory settings.
Setting range
1, 2, 3
0 – 165 l/min
-
-
20 to 90 °C
Installation Manual auroMATIC 560 0020060907_00
Default setting
1
0
-
-
75 °C