Electrode report
Electrode report—stores automatically the electrode
history and measurement conditions
Calibration data
Calibration data—stores automatically the current
calibration
Delete data
The entire measurement data or electrode report log can be deleted to
remove data that has already been sent to a printer or PC.
1. From the main menu use the
confirm.
2. Use the
or
to select Erase and confirm.
3. Use the
or
to select Measurement data or Electrode report and
confirm. Confirm again to delete the data.
The entire log is deleted at once.
Send data to a printer or to a computer
N O T I C E
The data output (printer or PC) needs to be selected first, so that the Print menu
is available (refer to
Select the data output
Note: Refer to
Report output
on page 15 to select the report output type.
1. From the main menu use the
confirm.
2. Use the
or
to select Print and confirm. Select one of the
following options and confirm with
data, Electrode data, Calibration data, Calibration report or
Instrument condit.
or
to select DATA LOGGER and
on page 13).
or
to select DATA LOGGER and
to print the data: Measurement
Report output
N O T I C E
The data output (printer or PC) needs to be selected first, so that the Type of
report menu is available (refer to
Select the data output
Different report output types can be selected when a printer or a PC is
connected.
1. From the main menu use the
2. Use the
or
to select Type of report and confirm.
3. When a printer or a computer and Terminal is connected, use the
or
to select
Option
Description
Reduced Select Several or One sample as an output format
Standard Select Several or One sample as an output format. Select
several: Users: The user name appears on the printed report
(17 characters). Header:The company name can be added as a
header (40 characters) and appears on the print report. Identify
sensor:The sensor model and the sensor serial number can be
added and appears on the print report.
GLP
Select Several or One sample as an output format. Select
several: Users: The user name appears on the printed report
(17 characters). Header:The company name can be added as a
header (40 characters) and appears on the print report. Identify
sensor:The sensor model and the sensor serial number can be
added and appears on the print report.
4. When a computer is connected and LabCom Easy (refer to
the data output
on page 13 for more information) is selected, use the
or
to select
Option
Description
Users
The user name appears on the printed report
(17 characters).
Identify sensor The sensor model and the sensor serial number can be
added and appears on the print report.
on page 13).
or
to select SYSTEM. Confirm.
Select
English 15