3.3.3 System screen
System screen
Sensor
Collector
Pump
Store heat exchanger
Collector
with collector sensor
Store
with heat exchanger
26
The system screen shows the system. The screen con-
sists of several system component symbols, which are
flashing depending on the current status of the system
(see chap. 3.5.1).
Store sensor top
Store
Sensor
Temperature sensor
Pump
Electric afterheating
(electric immersion heater)
3.4

Slide switch

The allocated relay (see p. 13) can be manually swit-
ched on (I), switched off (O) or put into automatic
mode (AUTO) by means of the slide switch.
• Manually OFF
• Manually ON
• Automatic mode = Auto (centre)
Slide switch
Electric
afterheating
3.5

Flashing codes

3.5.1 System screen flashing codes
• Pump symbols are flashing if the corresponding
relay is active
• Sensor symbols are flashing when the correspon-
ding sensor display channel is selected
• Sensors are flashing quickly in the case of a sensor
fault
3.5.2 LED flashing codes
green:
red/green flashing: initialisation phase
red flashing:
= 0 (left)
= I (right)
everything OK
manual mode
sensor defective
(sensor symbol is flashing quickly)