Sharp TU-45GD1E Service Manual page 35

Hide thumbs Also See for TU-45GD1E:
Table of Contents

Advertisement

(9) Set the 5th point (P5) to the designated gradation and calculate the G set value of the 5th point using the
following formula: G initial value of the 5th point x (G adjustment value of the 6th point/928) (rounding off
fractions). Then adjust RB to obtain the standard value of the 5th point.
(10) Adjust CALC to 1 and calculate. Confirm that the adjustment has been made correctly to exit.
[Tentative value]
Standard value 1: x=0.272, y=0.277 [Minolta CA-110] (192 gradations) (P1)
Standard value 2: x=0.272, y=0.277 [Minolta CA-110] (352 gradations) (P2)
Standard value 3: x=0.272, y=0.277 [Minolta CA-110] (528 gradations) (P3)
Standard value 4: x=0.272, y=0.277 [Minolta CA-110] (656 gradations) (P4)
Standard value 5: x=0.272, y=0.277 [Minolta CA-110] (800 gradations) (P5)
Standard value 6: x=0.278, y=0.285 [Minolta CA-110] (928 gradations) (P6)
3) Connections
W/B analyzer
OSD display
x=0.272
y=0.277
4) Remarks
If W/B analyzer is not available, adjust the W/B by visually comparing with other units.
LCD TV
35
OSD display
PATTERN
PAGE2
ADJ6
CAL C0
POINT1
0192
P1
0192 0189 0181
P2
0358 0347 0332
P3
0532 0520 0506
P4
0662 0646 0641
P5
0802 0788 0797
P6
0928 0914 0923
TU-45GD1E
LC-45GD1E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-45gd1e

Table of Contents