PRES S UR E/ E X T R A S E N S OR AR EA
Pressure
Your Relative Pressure reading will come from your station's internal
barometer. Allow up to 10 days for automatic calibration or program
your local pressure value in the Settings Menu. The arrows on the left
represent rising and falling tendency.
Extra Sensors
This station can display data for up to 3 extra Temperature and
Humidity, or Rain Sensors.
Pressure (default)
Rain
Temperature/Humidity
Add Extra Sensors
1. Install batteries into your extra sensor(s).
Note: For Temp/Humidity sensors, be sure to select different
channels (1,2,3) before you insert batteries.
2. Hold the EXTRA button until the Reception Indicator
starts to
animate. This will start a search for your sensors.
3. Your sensor(s) should connect within the next few minutes. Press
the EXTRA button to cycle through Extra Sensor and Pressure
data. The Auto Scroll Icon
will appear when activated.
Note: While viewing Extra Sensors, hold the MINUS button to delete.
Purchase Extra Sensors
Visit
lacrossetechnology.com/products/CA76669#parts
to find and
purchase compatible add-on sensors.
Page 5
BUT TON FUN CT IONS
Hold to enter Alert Settings.
ALERTS
Alerts: Press to move to next item.
Press to view Pressure or Extra Sensors (if added).
EXTRA
Hold to search for all sensors.
Settings: Press to increase values.
+ (PLUS)
Alerts: Press to arm/disarm alerts.
SET
Hold to enter Settings Menu.
Settings: Press to decrease values.
Alerts: Press to arm/disarm alerts.
- (MINUS)
History: Hold to reset History Records.
Extra Sensors: While viewing Extra Sensors, hold to delete sensor.
HISTORY
Press to view History Records.
Press to adjust backlight.
LIGHT
Hold to enter Auto Dim Settings.
ALERTS & LIGHT
Hold to Factory Reset station.
WARR AN T Y
La Crosse Technology, Ltd. provides a 1-year limited time warranty (from date
of purchase) on this product relating to manufacturing defects in materials and
workmanship.
Before returning a product, please contact our friendly customer support with
questions:
Springfield Instruments Inc.
104 Barr St.
Saint Laurent, Québec
H4T 1Y4
Customer Service:
1-844-687-4040
info@springfieldinstruments.com
Page 6
SEN SO R WEAT HE R SH IE LD
• The Sensor Weather Shield is designed to protect your
outdoor sensor from rain and snow.
• This shield will offer limited protection from the sun's heat.
• Optional purchase at:
bit.ly/925-1418
Sold separately
SPE C IFICATIO N S
Indoor:
Temperature Range: 32 F to 122F (0C to 50C)
Humidity Range: 10% - 99% RH
Relative Pressure Range: 23.62 to 32.48 inHg (800 to 1100 hPa)
Outdoor:
Temperature Range: -40°F to 140°F (-40°C to 60°C)
Humidity Range: 10% - 99% RH
Transmission Range: over 330 feet (100 meters) in open air RF 433MHz
Power Requirements:
CA76669: 5-volt power adapter (included) AC6: HX075-050600-AU-00
Optional: 3 "AA" LR6 Batteries (not included)
The plug on the power adapter is intended to serve as the disconnect device, the
socket-outlet shall be installed near the equipment and shall be easily accessible.
TX141TH-Bv3: 2 "AA" LR6 Batteries (not included)
Battery Life:
CA76669: 48-60 months with power cord as primary power
TX141TH-Bv3: Over 24 months with reputable batteries
Dimensions:
CA76669: 8.98" L x 1.14" W x 5.43" H (22.8cm L x 2.9cm W x 13.8cm H)
TX141TH-Bv3: 1.57" L x 0.79" W x 5.11" H (3.98cm L x 2.0cm W x 13.0cm H)
Page 7
CARE + M AI NT EN ANC E
• Do not mix old and new batteries.
• Do not mix Alkaline, Lithium, standard, or rechargeable batteries.
• Always purchase the correct size and grade of battery most suitable for use.
• Clean the battery contacts and also those of the device prior to battery
installation.
• Ensure the batteries have with correct polarity (+ / -).
• Remove batteries from equipment that will not to be used for an extended period.
• Promptly remove expired batteries.
CAN ADA STATE M ENT
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Inno-
vation, Science and Economic Development Canada's licence-exempt RSS(s).
Operation is subject to the following two conditions:
(1 ) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
All rights reserved. This manual may not be reproduced in any form, even in part, or
duplicated or processed using electronic, mechanical or chemical process without
the written permission of the publisher. This booklet may contain errors or misprints.
The information it contains is regularly checked and corrections are included in
subsequent editions. We disclaim any responsibility for any technical error or
printing error, or their consequences.
All trademarks and patents are recognized.