You can connect multiple battery modules together to form a single large battery by connecting the
RJ-45 cable supplied by Pylontech using the link ports on the battery. This is shown in more detail in
the
example wiring diagram
The communications for UP2500 can be paralleled up to 20 modules per string (and cannot use the
LV-HUB). Other models can connect up to 8 battery modules (see Pylontech data sheets), in those
models when using more than 8 parallel units, some limitations, additional configuration or equipment
(e.g. Pylontech LV-Hub) may apply. See your Pylontech dealer, and Pylontech documentation for more
details.
The batteries will automatically detect and link to each other, no adjustment of dip switches on the
battery module are necessary.
The battery with the empty link port 0 is the master battery.
Type A cable
The Victron VE.Can to CAN-bus BMS type A Cable, part number ASS030710018 is used for connection
with US2000C / US3000C / UP5000 / Force-L.
Type B cable
The Victron VE.Can to CAN-bus BMS type B Cable, part number ASS030720018 is used for connection
with US2000 / US3000 / UP2500;
Note you cannot use the comms cable supplied by Pylontech for this connection between the master
battery and the GX device.