Example Applications; Retrieving Bios Settings - HP xw4300 Technical White Paper

Hp xw4300: supplementary guide
Hide thumbs Also See for xw4300:
Table of Contents

Advertisement

Status

Example applications

Retrieving BIOS Settings

The following script will enumerate all the available settings within a computer. This example uses
semi-synchronous access for the purpose of simplifying the example. However, the interface supports
either semisynchronous or asynchronous access.
"Critical Failure" (25) - The element is non-functional and recovery
MAY NOT be possible.
"Major Failure" (20) - The element is failing. It is possible the some or
all of the functionality of this component is degraded or not working.
"Minor Failure" (15) - All functionality is available but some MAY be
degraded.
"Degraded/Warning" (10) - The element is in working order and all
functionality is provided. However, the element is not working to the
best of its abilities. For example, the element may not be operating at
optimal performance or it may be reporting recoverable errors.
"OK" (5) - The element is fully functional and is operating within normal
operational parameters and without error.
"Unknown" (0) - The implementation can not report on Severity at this
time.
Indicates the current status(es) of the element. Various operational
statuses are defined. Many of the enumeration's values are
self-explanatory. However, a few are not and are described in more
detail.
"Stressed" indicates that the element is functioning, but needs attention.
Examples of "Stressed" states are overload, overheated, etc.
"Predictive Failure" indicates that an element is functioning nominally
but predicting a failure in the near future.
"In Service" describes an element being configured, maintained,
cleaned, or otherwise administered.
"No Contact" indicates that the monitoring system has knowledge of
this element, but has never been able to establish communications with
it.
"Lost Communication" indicates that the ManagedSystemElement is
known to exist and has been contacted successfully in the past, but is
currently unreachable.
"Stopped" and "Aborted" are similar, although the former implies a
clean and orderly stop, while the latter implies an abrupt stop where
the element's state and configuration may need to be updated.
"Dormant" indicates that the element is inactive or quiesced.
"Supporting Entity in Error" describes that this element may be "OK"
but that another element, on which it is dependent, is in error. An
example is a network service or endpoint that cannot function due to
lower layer networking problems.
"Completed" indicates the element has completed its operation. This
value should be combined with either OK, Error, or Degraded so that a
client can till if the complete operation passed (Completed with OK),
and failure (Completed with Error). Completed with Degraded would
imply the operation finished, but did not complete OK or report an
error.
"Power Mode" indicates the element has additional power model
information contained in the Associated PowerManagementService
association.
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dx7200 - microtower pcClient management interface

Table of Contents