Download Print this page

Specifications - ADC HiGain H2TU-R-402 List 1B Quick Installation

List 1b and list 1c remote units

Advertisement

T
H2TU-R-402 L
HE
The HiGain H2TU-R-402 List 1B and List 1C remote units are the customer premises
side of a repeaterless T1 transmission system. The system provides 1.544 Mbps
transmission of a T1 payload on one unconditioned pair over the full Carrier Service
Area (CSA) range. The CSA includes loops up to 12,000 feet using 24 AWG wire or
up to 9,000 feet using 26 AWG wire.
Enhanced firmware allows the H2TU-R-402 List 1B and List 1C to be deployed in the
Wideband 3190 protection switching applications. These applications have the
following system requirements: two HXU-358 Multiplexers (software version 1.04 or
higher), an HMU-319 List 7A or List 7C Management Unit (software version 3.06 or
higher), an H2TU-C-319 List 2 Line Unit, and an HRE-206 Remote Enclosure
equipped with a PSC-606 Protection Switching Controller.
F
EATURES
• Status Light Emitting Diodes (LEDs) for Digital
Signal Level 1 (DS1) and HDSL2
• Craft port for maintenance terminal access to
HDSL2 provisioning screens
• Supports automatic protection switching
• DS1 transmit (IN) and receive (OUT) bridging
test jacks
• Local or line power (List 1B) or
line power only (List 1C)
• Transceiver optimized to adapt to cable
impairments
• Bit Error Rate Tester (BERT)
S
PECIFICATIONS
Operating Temperature
Operating Humidity
Local Power (List 1B option)
Line or Local Power Consumption
Sealing Current Option (List 1B
only)
Electrical Protection
Mounting
HDSL2 Line Rate
HDSL2 Output
DS1 Pulse Output
Maximum Provisioning Loss
DS1 Line Rate
DS1 Line Format
DS1 Frame Format
1B
L
IST
AND
• Lightning and power cross-protection on
• 1.552 Mbps full-duplex Overlapped PAM
• Generic and addressable repeater loopback
• Remote provisioning
• Narrow 200 mechanics
• Ultra-low wander
• List 1B sinks sealing current from H2TU-C
• Report generation and downloading
-40°F to +149°F (-40°C to +65°C)
5% to 95% (non-condensing)
-48 Vdc nominal (-42.5 to -56.5 Vdc)
4.5 W
Sinks 10 mA sealing current from H2TU-C line unit
Secondary surge and power cross-protection on all DS1 and
HDSL2 ports
Any 400 or 200 mechanics shelf
1.552 Mbps Overlapped Pulse Amplitude Modulated
Transmission with Interlocking Spectra (OPTIS)
+16.5 dBm ±0.5 dBm at 135Ω
0 dB, -7.5 dB, -15 dB
35 dB at 196 kHz, 135Ω
1.544 Mbps ±200 bps
Alternate Mark Inversion (AMI) or Bipolar with 8-Zero
Substitution (B8ZS)
Extended SuperFrame (ESF), SuperFrame (SF), or Unframed
(UNFR)
1C
IST
HDSL2 and DS1 interfaces
Transmission with Interlocking Spectra
(OPTIS) HDSL2 transmission on a single pair
activation codes

Advertisement

loading

This manual is also suitable for:

Higain h2tu-r-402 list 1c