4 Pipe connections Contact information General Symbol key Pipe coupling, heating medium 5 Electrical connections General Accessibility, electrical connection Connections 6 Commissioning and adjusting Preparations Filling and venting Start-up and inspection Post adjustment and venting NIBE S2125 Table of Contents...
This symbol indicates important information about what you should consider when installing Read the User Manual. or servicing the installation. Read the Installer Manual. This symbol indicates tips on how to facilitate using the product. Chapter 1 | Important information NIBE S2125...
Serial number The serial number can be found on the rear cover and at the bottom on the side. Caution You need the product's (14 digit) serial number for servicing and support. NIBE S2125 Chapter 1 | Important information...
Stainless steel, 3x400 V With integrated EMK 300 Part no. 069 109 Part no. 069 203 VVM 320 VVM 500 Stainless steel, 3x400 V Copper, 3x400 V Part no. 069 108 Part no. 069 400 Chapter 1 | Important information NIBE S2125...
• Place the heat pump in a suitable location outdoors to prevent any risk of the refrigerant flowing in through Do not place S2125 directly on the lawn or other non ventilation openings, doors or similar openings in the solid surface.
Page 10
If S2125 needs to be transported across soft ground, such as a lawn, we recommend using a crane truck that can lift it to the installation location. When S2125 is lifted with a crane, the packaging must be untouched. If a crane vehicle cannot be used the S2125 can be transported on an extended sack truck.
INSTALLATION AREA The distance between S2125 and the house wall must be at least 350 mm, but not more than 500 mm in locations that are exposed to the wind. The free space above S2125 must be at least 1,000 mm. The free space in front must be at least 1,000 mm for any future servicing.
Frost free Frostfritt djup depth Route the pipe downward from S2125. The condensation water pipe must have a water seal to prevent air circulation in the pipe. If the house has a cellar the stone caisson must be po- Caution sitioned so that condensation water does not affect the house.
Install the non-return valve. Fit the clip. Twist the clip to ensure that it fastens properly. Assemble the parts of the safety valve. Ensure that the arrow for the outlet is pointing down, as illus- trated. Chapter 2 | Delivery and handling NIBE S2125...
Page 15
Fit the left-hand half in the same way. Put the lid on. Secure with three screws. Two screws in the lid, on the right and left-hand sides, and one screw in the bottom. NIBE S2125 Chapter 2 | Delivery and handling...
Page 16
Screw the flexible pipes into place. The flexible pipes can be installed angled straight back or down, de- pending on which of the pipe connections the 90° Chapter 2 | Delivery and handling NIBE S2125...
Page 19
BT28 D at a la be BT16 XL40 S e ri e n r. RM1.2 NIBE S2125 Chapter 3 | The heat pump design...
Page 20
PIPE CONNECTIONS MISCELLANEOUS Connection, heating medium out of S2125 Type plate Connection, heating medium in to S2125, Serial number XL20 Service connection, high pressure Sign, pipe connections XL21 Service connection, low pressure Cable gland, incoming supply XL40 Connection, drain condensation water trough Designations according to standard EN 81346-2.
An undersized system can result in damage to Reversing valve/shunt the product and lead to malfunctions. Control module S2125 can only operate up to a return temperature of Air/water heat pump about 65 °C and an outgoing temperature of about 75 °C from the heat pump.
There is a difference between connection to a PRESSURE DROP, CONDENSER control module compared with connection to Tryckfall S2125 an indoor module. See also the Installer Pressure drop Tryckfall Manual for your control module/indoor module.
"Technical specifications" for fuse size. and damage. • If the building is equipped with an RCD, S2125 must be equipped with a separate one. NOTE • S2125 must be installed via an isolator switch. The...
At installation, install the screwed connection on the rear of the heat pump. The part of the screwed joint that tensions the cable must be tightened to a tightening torque above 3.5Nm. Incoming supply Connection Chapter 5 | Electrical connections NIBE S2125...
Page 27
S2125 S2125 AA2:X21 Compressor blocking Connect external control voltage (230V~ 50Hz) to termin- al block X5:L, X5:N and X5:PE (as illustrated). S2125 External F2120 Externt AA2:X5 NIBE S2125 Chapter 5 | Electrical connections...
Page 28
S2125 communicates with NIBE indoor modules/control Software version modules by connecting a three-core, screened cable In order for S2125 to be able to communicate with in- (max area 0.75 mm²) to terminal block X22:1–4. door module (VVM)/control module (SMO), you may For connection of indoor module/control module, see need to update to a more recent software version.
Page 29
F212X F212X AA2:X23 AA2:X23 AA2:X22 AA100:X9 SMO 20 AA2:X22 AA2:X22 S2125 F2120 SMO S40 Control module Control module AA100:X9 SMO 40 F2120 F2120 S2125 S2125 AA2:X23 AA2:X23 AA2:X22 AA2:X22 Control module AA5 X4 NIBE S2125 Chapter 5 | Electrical connections...
Page 30
(AA2). DIP switch S1 is used for configuration of address and functions. For cascade operation with SMO for ex- ample, addressing is required. S2125 has the address 1 as standard. In a cascade connection all S2125 must have a unique address. The address is coded in binary. NOTE Only change the DIP switches position when the product is not powered.
S1 position 4 must be changed according to NOTE the description in section "Cooling". Turn the isolator switch on. Do not start S2125 if there is a risk that the water in the system has frozen. Ensure that the S2125 is connected to the power source.
For correct function of the heat pump over the entire year, the charge flow must be correctly adjusted. If an NIBE indoor module VVM or accessory controlled charge pump is used for the control module SMO, the control tries to maintain an optimal flow across the heat pump.
S2125 communicates with the NIBE indoor module/con- K4, K5 tion trol module, which means that all settings and measure- Continuous Relay engaged ment values from S2125 are adjusted and read off on light the indoor module/control module. N-RELAY No function Caution COMPR.
Master control To control S2125, a NIBE indoor module/control module is required, which calls upon S2125 according to de- mand. All settings for S2125 are made via the indoor module/control module. It also shows the status and sensor values from S2125.
S2125 counts the time to "active defrosting" for The ambient temperature is locked and the high re- each minute that the compressor is running, to create turn temperature alarm is blocked for two minutes a defrosting requirement.
Setting range S2125 1 x 230 V: off/on Current limit Setting range S2125 1 x 230 V: off/on Max. current Setting range S2125 1 x 230 V: 6 – 32 A blockFreq 1 Setting range: on/off From frequency Setting range: 25 – 117 Hz To frequency Setting range: 28 –...
Page 37
Fan de-icing: Here, you set whether the "fan de-icing" if you have S2125 230V~50Hz. During active function, function will be activated during the next "active defrost- you can limit the value of the maximum current.
Page 38
Detect compressor phase for servicing or if necessary. This can be justified togeth- er with "fan de-icing". Setting range S2125 1 x 230 V: off/on Start temperature for defrost function: Here, you set Current limit the temperature (BT16) at which the defrost function Setting range: 6 –...
Alarms are acknowledged on the indoor mod- ule / control module (VVM / SMO). S2125 NOT COMMUNICATING • Check that S2125 is correctly installed in the indoor If the operational interference is not shown in the display module (VVM) or the control module (SMO).
10 °C. • If the temperature of the evaporator (BP8) falls below its lowest permitted value. After failing to defrost ten times, S2125 must be checked. This is indicated by an alarm. Chapter 8 | Disturbances in comfort...
Sensor BT14 or BP9 has come loose The discharge sensor, BT14, loose or defective or is otherwise defective. or high pressure sensor, BP9, has come loose and is not giving correct measure- ment values. Chapter 8 | Disturbances in comfort NIBE S2125...
Page 43
The output current from the inverter Disruption in supply voltage. pressor to the compressor has been tempor- Poor heating medium flow. arily too high 3 times within 2 hours Defective compressor. or continuously for 1 hour. NIBE S2125 Chapter 8 | Disturbances in comfort...
Page 44
Incorrect PCB in heat The heat pump has the wrong con- The control board has been pump. Change to a new trol board. replaced with a control board PCB suitable for S2125. for F2120. Chapter 8 | Disturbances in comfort NIBE S2125...
9 Accessories Detailed information about the accessories and complete accessories list available at nibe.eu. Not all accessories are available on all markets. CONDENSATION WATER PIPE Condensation water pipe, different lengths. KVR 11-10 1 metres Part no. 067 823 KVR 11-30 3 metres Part no.
Sound levels S2125 is usually placed next to a house wall, which gives a directed sound distribution that has to be taken into consideration. Accordingly, when setting up, you should always attempt to select the side that faces the least sound-sensitive neighbouring area.
0.12 – 0.48 Min. design flow, defrosting (100% pump speed) 0.32 Min./max. HM temp, continuous operation °C 26 / 75 Connection heating medium S2125 G1” external thread Connection heating medium flex pipe G1” external thread Chapter 10 | Technical data NIBE S2125...
Page 49
Scale for the product’s room heating efficiency class A++ to G. Control module model SMO S Scale for the system’s room heating efficiency class A+++ to G. Control module model SMO S NIBE S2125 Chapter 10 | Technical data...
Page 50
POWER DURING HEATING OPERATION Maximum and minimum capacity during continuous Supply temperature Framledningstemperatur (°C) (°C) operation. Defrosting is not included. S2125-8 Maximal och mininimal uppvärmningseffekt S2125-8 Uppvärmningseffekt Heating output (kW) (kW) -30 -25 -20 -15 -10 -5 10 15 20 25 30 35 40 45...
Page 51
POWER DURING COOLING OPERATION Maximum and minimum capacity during continuous operation. S2125-8, -12 S2125 Maximal och mininimal kyleffekt Kyleffekt Cooling output (kW) (kW) 12,0 10,0 Utomhustemperatur Outdoor temperature (°C) (°C) Framledningstemperatur 18 °C Supply temperature 18°C Framledningstemperatur 7 °C Supply temperature 7°C...
The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added to the package, the overall efficiency of the package should be recalculated. Chapter 10 | Technical data NIBE S2125...
Page 53
- / 49 Nominal heating medium flow Annual energy consumption 2,939 Brine flow brine-water or water-water heat pumps Contact information NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – Sweden NIBE S2125 Chapter 10 | Technical data...
Page 54
- / 49 Nominal heating medium flow Annual energy consumption 4,102 Brine flow brine-water or water-water heat pumps Contact information NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – Sweden Chapter 10 | Technical data NIBE S2125...
Inspection of the installation, 6 Master control, 34 Safety information, 4 Control module, 8 Indoor module, 8 Inspection of the installation, 6 Installation area, 11 Delivery and handling, 9 Installing the installation Assembly, 9 Symbol key, 23 Compressor heater, 31 NIBE S2125 Item register...
Page 64
Large amount of water below S2125, 40 LED status, 33 Low hot water temperature or no hot water, 39 Low room temperature, 40 Marking, 4 Master control, 34 Pipe connections, 23 Charge pump, 24 General, 23 Pipe coupling, heating medium, 24...
Tel: +46 (0)433-27 3000 info@evan.ru info@nibe.se nibe-evan.ru nibe.se SWITZERLAND NIBE Wärmetechnik c/o ait Schweiz Industriepark, CH-6246 Altishofen Tel. +41 (0)58 252 21 00 info@nibe.ch nibe.ch For countries not mentioned in this list, contact NIBE Sweden or check nibe.eu for more information.
Page 68
WS release date: 2021-05-27 15:29 Publish date: 2021-06-14 09:40 This manual is a publication from NIBE Energy Systems. All product illustrations, facts and data are based on the available information at the time of the publication’s approval. NIBE Energy Systems makes reservations for any factual or printing errors in this manual.