 Lift the pump, Motor and base frame assembly with the help of slings of adequate
strength suitably fastened at appropriate locations marked on the base frame (see
figure).
 Now lower it on to the place provided on the foundation suitably.
 Using wedges, placed as close to the foundation bolts as possible, raise the pump to the
desired elevation.
discharge flanges are vertical.
ALIGNMENT.
guidelines provided under "GROUTING" to the complete the installation.
8 |
P a g e
Hoisting of pumping units
Placement of wedges for leveling
Using a sprit level, dust the wedges so that the suction and
Align the coupling as mentioned in the instructions for COUPLING
Grouting of Pump-Motor-Base should be carried out as per the
.