  • Page 1 Turbo Air Speeds up the Pace of Innovation Underbar Equipment Club Top Beer Dispensers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! TCB-2SD TCB-2SB TCB-3SD TCB-3SB TCB-4SD TCB-4SB SD series: Stainless Steel Exterior SB series: Black Laminated Vinyl Exterior or Black Powder Coating Exterior www.turboairinc.com...
  • Page 2: Table Of Contents

    LINE INSTALLATION SCHEMATIC DIAGRAM CAUTION "IMPORTANT" INSTALLATION CLEANING BASIC OPERATION TROUBLESHOOTING WARRANTY 11-12 SPECIFICATIONS MODEL COMPH.P. V/Hz REFRIGERANT AMPS WEIGHT TCB-2SD/SB 115V/60Hz R-134a 7.0A 355 lbs TCB-3SD/SB 115V/60Hz R-134a 7.0A 375 lbs TCB-4SD/SB 115V/60Hz R-134a 7.5A 445 lbs SERIAL NUMBER The serial number is located on the rating label which is on interior left side wall.
  • Page 3: Installation Of The Draft Arms Towers Installation Schematic Diagram

    INSTALLATION OF THE CASTERS According to model, refer to the assembly position of casters. TCB-2SD, TBD-2SD, TBB-2SB, TBB-2SG TCB-3SD, TBD-3SD, TBB-3SB, TBB-3SG TCB-4SD, TBD-4SD, TBB-4SB, TBB-4SG This picture is a plan view of bottom cabinets. CB is an abbreviation of the caster with a brake.
  • Page 4: Beer Line & Co

    BEER LINE & CO LINE Installation Schematic Diagram Distributor Fixture Line Beer Line#1 Beer Line#2 Beer #1 Beer #2 TCB-2SD, TCB-3SD, TCB-4SD TCB-2SB, TCB-3SB, TCB-4SB * Assemble BEER LINE & CO LINE as above drawing.
  • Page 5: Caution "Important

    CAUTION "IMPORTANT" DIRECT DRAW On direct-draw dispensers the drain is located at the front of the cabinet. To plumb in the drain, connect 5/8” P.V.C. pipe to the 5/8” barbed fitting supplies with the unit. * Don't pull out or Turn drain line.
  • Page 6 CAUTION "IMPORTANT" A. Excessively opening the door will cause the breakdown. B. Handle with care as shutting the door. 1. POWER CORD - Be sure the power cord is connected to the proper voltage, and amps should be run before connecting power cord to outlet. - A protected circuit of the correct voltage and amperage must be run for connection of the line cord.
  • Page 7: Installation

    1. GOOD AIR CIRCULATION - Do not place any object that will restrict air flow in front or back grills. - Turbo air highly recommends that there is ample space in rear of unit. 3 inches or more is best.
  • Page 8: Cleaning

    CLEANING Before cleaning, unplug the unit. 1. CLEANING THE INTERIOR AND EXTERIOR - The interior and exterior of the unit can be cleaned using warm water with soap. - Do not use an abrasive cleaner because it will scratch the surface. 2.
  • Page 9: Basic Operation

    BASIC OPERATION REFRIGERATORS 1. The controller(thermostat) is located at the back right inside of the unit. 2. The factory setting maintains about 38˚F(3˚C) inside. 3. Set toward “counter clock wise” warmer temperature and “clock wise” for colder temperature. Temperature Controller (Thermostat) 4.
  • Page 10: Troubleshooting

    TROUBLESHOOTING SYMPTOMS CAUSES SOLUTIONS Cooler is freezing • Thermostat set too cold. • Turn the temperature dial to a products warmer setting. The unit does not • There is a power connection • Check the power cord to make refrigerate at all. failure problem.
  • Page 11 THREE YEAR WARRANTY Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, under normal use and service, for a period of three (3) year from the date of original installation or 39 months after shipment date from Turbo Air , whichever occurs first.
  • Page 12 3. ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FLOOD, ACTS OF GOD. TURBO AIR is not responsible for the repair or replacement of any parts that Turbo Air determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, flood, or an Act of God.
  • Page 13: Warranty

    (3) year from the date of original installation or 39 months after shipment date from Turbo Air, whichever occurs first. Any part, covered under this warranty, that are by Turbo Air to have been defective within three (3) year of original installation or thirty-nine (39) months after shipment date from manufacturer, whichever occurs first, is limited to the repair or replacement, including labor charges, of defective parts or assemblies.