Turbo Air TBD-1SD Installation And Operation Manual
Turbo Air TBD-1SD Installation And Operation Manual

Turbo Air TBD-1SD Installation And Operation Manual

Beer dispenser & back-bar cooler
Hide thumbs Also See for TBD-1SD:

Advertisement

Turbo air Speeds Up the Pace of Innovation
Beer Dispenser & Back-Bar Cooler
Installation and Operation Manual
Please read this manual completely before attempting to install or operate this equipment!
TBD-1SD, TBD-2SD, TBD-3SD, TBD-4SD(Stainless Steel)
TBD-1SB, TBD-2SB, TBD-3SB, TBD-4SB(Black Paint)
TBB-1SB, TBB-2SB, TBB-3SB, TBB-4SB(Solid Door)
TBB-2SG, TBB-3SG, TBB-4SG(Glass Door)
This equipment is intended for the storage and display of non-potentially hazardous, bottled or canned
products only
TCB-2SD,TCB-3SD, TCB-4SD(Stainless Steel)
TCB-2SB,TCB-3SB, TCB-4SB(Black Paint)

Advertisement

Table of Contents
loading

Summary of Contents for Turbo Air TBD-1SD

  • Page 1 Turbo air Speeds Up the Pace of Innovation Beer Dispenser & Back-Bar Cooler Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! TCB-2SD,TCB-3SD, TCB-4SD(Stainless Steel) TCB-2SB,TCB-3SB, TCB-4SB(Black Paint) TBD-1SD, TBD-2SD, TBD-3SD, TBD-4SD(Stainless Steel)
  • Page 2: Table Of Contents

    CLEANING ....................... 8 BASIC OPERATION ..................9 BEFORE REQUESTING SERVICE ............... 10 WARRANTY....................11~12 SERIAL NUMBER The serial number is located on the rating label which is on interior left side wall. Please retain the unit’s serial number for service purpose. Turbo air...
  • Page 3: Installation Of The Casters

    DRAFT ARMS TOWERS Installation Schematic Diagram Screw(M4xL12) x 4EA Screw(M4xL12) x 4EA Draft Tower Assembly Rubber Gasket Draft Tower Assembly Rubber Gasket TCB-2SD, TCB-3SD, TCB-4SD TBD-2SD, TBD-3SD, TBD-4SD TBD-2SB, TBD-3SB, TBD-4SB * Assemble DRAFT TOWER as above drawing. Turbo air...
  • Page 4: Beer Line & Co Line Installation Schematic Diagram

    BEER LINE & CO LINE Installation Schematic Diagram Distributor Fixture Line Beer Line#1 Beer Line#2 Beer #1 Beer #2 TCB-2SD, TCB-3SD, TCB-4SD TBD-2SD, TBD-3SD, TBD-4SD TBD-2SB, TBD-3SB, TBD-4SB * Assemble BEER LINE & CO LINE as above drawing. Turbo air...
  • Page 5: Caution "Important

    On direct-draw dispensers the drain is located at the front of the cabinet. To plumb in the drain, connect 5/8” P.V.C. pipe to the 5/8” barbed fitting supplies with the unit. * Don't pull out or Turn drain line. Turbo air...
  • Page 6 - Unplug the unit, whenever performing maintenance functions or cleaning the refrigerated cabinet. - Compressor warranty is void if burnt out due to low voltage. 2. RE-STARTING - If unpluged, wait 5 minutes before re-starting. Turbo air...
  • Page 7: Installation

    1. GOOD AIR CIRCULATION - Do not place any object that will restrict air flow in front or back grills. - Turbo air highly recommends that there is ample space in rear of unit. 3 inches or more is best.
  • Page 8: Cleaning

    - Empty the Drain Pan which is located under the unit, periodically. - When reinstalling Drain Pan, make sure Drain Hose is placed back in pan. 5. CHECK AFTER CLEANING - Plug unit back in. - Check that the unit is operating properly. Turbo air...
  • Page 9: Basic Operation

    3. Set toward “counter clock wise” warmer temperature and “clock wise” for colder temperature. Temperature Controller (Thermostat) 4. The thermostat controls compressor’s cycling by sensing inside temperature. 5. When unit will not be used for a long time, unplug the unit. Turbo air...
  • Page 10: Before Requesting Service

    The following points are not malfunctions: • A water-flowing sound can be heard when the compressor stops. This is the sound of REFRIGERANT flowing. • The compressor does not run during the defrost cycle. Turbo air...
  • Page 11: Warranty

    Turbo Air and upon proper installation and start-up in accordance with the instruction packet supplied with each Turbo Air unit. Turbo Air’s obligation under this warranty is limited to a period of one (1) year from the date of original installation or 15 months after shipment date from Turbo Air, whichever occurs first.
  • Page 12 ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FLOOD, ACTS OF GOD. Turbo Air is not responsible for the repair or replacement of any parts that Turbo Air determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, flood, or act of God.
  • Page 13 1250 Victoria street CARSON, CA 90746 TEL: 310-900-1000 FAX: 310-900-1077 Toll Free: 1-800-627-0032 (U.S.A. In Canada) http://www.turboairinc.com Turbo air...

Table of Contents