REMOVING THE COMBUSTION CHAMBER LINING

REMOVING THE COMBUSTION CHAMBER LINING
The combustion chamber lining protects the body of the fireplace insert from the
heat of the fire. The widely fluctuating temperatures can cause the combustion cham-
ber lining to crack. This will not affect the functionality of the fireplace insert. The lin-
ing does not need to be replaced until, after several years of use, it begins to crumble.
The liner panels are easy to place in position in the fireplace insert and can easily be
replaced by you or your dealer.
Procedure for removing the combustion chamber lining:
1.
Remove the flue panel (1) by pushing up the front and pulling it forward so that the
rear end disengages. The flue panel can now be carefully removed.
2. Side panels (2): pull the bottom of the panels forward and remove them.
3. Remove the rear panel (3) by pulling out the bottom of the panel.
4. Remove the rear panel (4) by pulling out the bottom of the panel.
5. Remove the bottom panels (5) by first removing the grate and ash drawer, and then
removing the bottom stones.