Flue System - AGA GC Installation Instructions Manual

Aga gas fired cookers installation instructions
Table of Contents

Advertisement

FLUE SYSTEM

The terminal is suitable for wall thicknesses from 228mm
to 600mm cut size
Should the installation of the appliance be in an unusual
location or restricted space, special procedures may be
necessary.
Terminal Position
The minimum acceptable spacings from the terminal to
obstructions and ventilation openings are as shown in the
diagram.
Where the terminal is fitted within 600mm below plastic
guttering an aluminium shield 1500mm long should be
fitted to the underside and immediately beneath the
guttering or eaves.
Where the terminal is fitted within 450mm below eaves or
painted guttering an aluminium shield 750mm long should
be fitted to the underside and immediately beneath the
guttering or eaves.
Minimum siting dimensions for Balanced Flue terminals
Position
A
Directly below an openable window,
air vent, or an other ventilation opening
B
Below gutter, drain/soil pipe
C
Below eaves
D
Below a balcony or car port roof
E
From vertical drain pipes and soil pipes
F
From internal or external corners
G Above adjacent ground or balcony level
H
From surface facing the terminal
I
Facing terminals
J
From opening (door/window)
in car port into dwelling
K
Vertical from a terminal
L
Horizontally from a terminal
Terminal Protection
A terminal guard is supplied with the cooker and must be
fitted if flue termination is less than 2 metres above
ground level, or subject to damage.
When fitted, it must be positioned to provide a minimum
of 50mm clearance from any part of the terminal and be
central over the terminal.
Minimum Spacing
mm
300
300
300
600
300
600
300
600
600
1200
1500
300
4
AROUND THE HOUSE
UNDER CAR PORT, ETC.
DESN 511052
DESN 511053