Nominal Data; Technical Description; Mounting Data; Transport And Storage Conditions - ebm-papst R2E210-AB34-05 Operating Instructions Manual

Table of Contents

Advertisement

R2E210-AB34-05

3.2 Nominal data

Motor
M2E068-DF
Phase
1~
Nominal voltage / VAC
230
Frequency / Hz
50
Method of obtaining
fa
data
Valid for approval/
CE
standard
-1
Speed (rpm) / min
2400
Power consumption / W
125
Current draw / A
0.56
Capacitor / µF
2.5
Capacitor voltage / VDB
400
Capacitor standard
S0 (CE)
Min. back pressure / Pa
0
Min. ambient
-25
temperature / °C
Max. ambient
45
temperature / °C
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change

3.3 Technical description

Weight
3.5 kg
Fan size
210 mm
Rotor surface
Partly cast in aluminum
Impeller material
Sheet steel, stainless
Support plate material
Sheet steel, hot-dip galvanized
Number of blades
6
Motor suspension
Motor mounted on support plate for one-
sided vibration damping
Direction of rotation
Counterclockwise, viewed toward rotor
Degree of protection
IP44; installation- and position-dependent
Insulation class
"F"
Moisture (F) /
H0 - dry environment
Environmental (H)
protection class
Installation position
Any
Condensation
None
drainage holes
Mode
S1
Motor bearing
Ball bearing
Touch current
< 0.75 mA
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Variable
Protection class
I (with customer connection of protective
earth)
Conformity with
EN 60335-1; CE
standards
Approval
EAC
Item no. 11881-5-9970 · ENU · Change 89188 · Approved 2016-08-26 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing
; Secure the screws against unintentional loosening (e.g. use self-
locking screws).
Strength class of
screws
Any further mounting data required can be taken from the product drawing.

3.5 Transport and storage conditions

; Use the device in accordance with its degree of protection.
Max. permitted
ambient temp. for
motor (transport/
storage)
Min. permitted
ambient temp. for
motor (transport/
storage)

4. CONNECTION AND STARTUP

4.1 Mechanical connection

; Check the device for transport damage. Damaged devices are not to
be installed.
; Install the undamaged device in accordance with your application.
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
8.8
+ 80 °C
- 40 °C
CAUTION
Cutting and crushing hazard when removing fan from
packaging
→ Carefully remove the device from its packaging, by the fan
impeller. Strictly avoid shocks.
→ Wear safety shoes and cut-resistant safety gloves.
NOTE
Damage to the device from vibration
Bearing damage, shorter service life
→ The fan must not be subjected to force or excessive vibration
from sections of the installation. #If the fan is connected to air
ducts, the connection should be isolated from vibration, e.g.
using compensators or similar elements. #Ensure stress-free
attachment of the fan to the substructure.
CAUTION
Possible damage to the device
If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of
installation until all fastening screws have been tightened.

Advertisement