BN Thermic HWP2-45 Series Instructions page 2

Infrared ip55 heater

Advertisement

2. INTRODUCTION & SPECIFICATION
This heater produces a totally dry heat, no condensation, no gas, no fumes and no smell. It reaches maximum heat output within seconds of being
turned on and has a highly polished aluminium reflector for maximum heat efficiency. It adjusts horizontally through 90° while mounted. And is
Ideal for industrial or domestic applications, IP55 rated.
Model
Power
Input supply
Dimensions (W x H x D)
Mounting Bracket Stand Off
Minimum Mounting Height
3. MOUNTING INSTALLATION
3.1
WALL MOUNTING (fig.1)
IMPORTANT! The following points should be noted:
The heater should always have a minimum
clearance of 500mm from a ceiling and at least
1000mm from any object.
IMPORTANT! Ensure that the mounting surface is
capable of supporting the weight of the heater.
IMPORTANT!
The heater should be mounted
horizontally where possible or at a maximum angle of
35 degrees from the horizontal.
IMPORTANT!
The
mounting
sufficiently earthed.
3.1.1 Remove the wall mounting bracket from the heater by
removing the two bolts from either end of the bracket.
3.1.2 Before drilling ensure that there are no wires or water
pipes in the area where the heater is to be placed.
3.1.3 Use the bracket as a template. Fix the metal bracket
to the wall by using a minimum of 3 holes and
appropriate fixings (not supplied).
3.1.4 Refit the heater back onto the bracket
3.1.5 Adjust the angle of heater to direct heat where
required, between 45° and 90° (see fig.1).
3.1.6 Now tighten up the two bolts tightly.
3.2
ELECTRICAL CONNECTION
3.2.1 Please make sure you have read the Safety
instructions and you are a suitably qualified
electrician before continuing.
3.2.2 If connecting to a 20A Round Pin Industrial Plug
a) Connect the GREEN/YELLOW earth wire to the
earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal
'L'.
c) Connect the BLUE neutral wire to the neutral
terminal 'N'.
d) After wiring, check that there are no bare wires, that
all wires have been correctly connected, that the cable
outer insulation extends beyond the cable restraint and
that the restraint is tight.
3.2.3 Connection to a Switched Fused Spur / Isolator.
a) Connect the GREEN/YELLOW earth wire to the earth connection.
b) Connect the BROWN live wire to the live connection.
c) Connect the BLUE neutral wire to the neutral connection'.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends
beyond the cable restraints and that the restraint is tight.
HWP2-45B
4500W
230V 50Hz 19.5A
1440 x 125 x 125mm
45mm
1.8m
bracket
must
be
HWP2-45BM
4500W
230V 50Hz 19.5A
1440 x 125 x 125mm
45mm
1.8m

Advertisement

loading

This manual is also suitable for:

Hwp2-45bHwp2-45bm