Operating instructions
HERMA 400
4.1.5
Label sensor FS03
680297
The label sensor FS03 is a self-learning unit, suitable for paper labels as well as electrically conducting
labels (metallized or aluminium-covered). The unit is set such that the sensor is high-active on the
label (1-signal on the label). The LED of the unit indicates the current switching output, i.e., it lights up
on the label and is off in the gap between the labels.
The FS03 comprises the operating modes „work mode" and „setting mode", described in the
following.
All adjustments, if required, are effected with the help of a single set button. States, results, and
signals are indicated via a LED which can take the two colors of green and red.
Work mode (normal mode)
This mode is the mode for normal operation. Any adjustments have been made already (see the
section „Setting mode").
Cross adjustment
1
LED
Set button
>
Slightly lift sensor at the front and slide into the desired position on
rail 1.
3.28 US (130519)
4
A
PPLICATOR DESCRIPTION
41/154
Need help?
Do you have a question about the 400 and is the answer not in the manual?