Trane 4TYK6524D1000AL Installation, Operation And Maintenance Manual page 9

U-match dc inverter system r-410a up to16 seer outdoor unit - cooling only and heat pump 24,000 to 60,000 btu/h - 60hz

Advertisement

Mounting of the Unit
If the unit is to be installed on a roof surface or on a concrete base, observe the following guidelines:
1. The provided base pan rises the heating pump 2" above the installation base.
2. If the unit is to be raised over the roof surface, use 4" x 4" boards (or equivalent) placed in a
Note: Avoid the blockage of drain openings as shown in Figure 3.
3. If the unit is to be raised to avoid seasonal snow/ice buildup, make sure the elevation support
Note: See Figure 4 for proper unit setting guidelines.
Figure 3. Recommended Rise Installation
Factory Recommendation for Mounting the Unit
1. Before installation, clean the mounting surface. Important = The cement base must comply
2. Center and level the unit over the base or mounting surface.
3. Using the provided L-shaped bracket, mark the boring holes over the concrete and bore holes
4. Tighten brackets and drill screws following conventional practices for the installation of these
MS-SVN052E-EN
manner that may allow weight to be evenly distributed and to prevent the transmission of noise
and vibrations. See Figure 3.
is sturdy enough to avoid unit's falling or tilting.
Concrete base or
other appropriate
material
with local codes and be thick enough to sustain the installation of fasteners.
of at least 1/4" additional depth as compared to the bracket to be used. Important = Drill
screws should not exceed 3/8" in length to avoid harming the coil.
supports. See Figure 4.
Note: Use one bracket at each side. For further stability, use 2 brackets at each side.
Note: Do not over-tighten brackets in order to avoid weakening the concrete material.
Unit Installation
Base pan (bottom view)
Avoid obstruction of
drain holes
Elevation above the
snow line
9