Alignment
Reverse ALC Adjustment
Connect the 150-Ohm Dummy Load to the "ANT" jack.
Press and hold in the [P1], [P2], [P0] and [P3] keys,
while turning the radio on, to enter the alignment
mode.
Press the [S2/2182] key (or [S1/ALARM] key) to se-
lect the alignment parameter "1R-ALC".
Press the PTT switch, then press the [ ] / [ ] key for
50 W on the PO meter of the VX-1400.
Release the PTT switch.
RPress the [S2/2182] key (or [S1/ALARM] key) to se-
lect the alignment parameter "2R-ALC".
Press the PTT switch, then press the [ ] / [ ] key for
50 W on the PO meter of the VX-1400.
Release the PTT switch.
Press the [S2/2182] key (or [S1/ALARM] key) to se-
lect the alignment parameter "3R-ALC".
Press the PTT switch, then press the [ ] / [ ] key for
50 W on the PO meter of the VX-1400.
Release the PTT switch.
Press and hold in the [MENU] button for 2 seconds to
save the new settings and exit from the alignment
mode.