Line Current *2)
Level
Load
Rated power
115 VAC
Standby with remote power off via NomadLink
Powered on, idling.
Pink noise
8 Ω / Ch.
700 x 4
11.6
(1/8 rated power)
16 Ω / Bridged
1400 x 2
4 Ω / Ch.
700 x 4
13.0
8 Ω / Bridged
1400 x 2
2 Ω / Ch.
300 x 4
9.4
4 Ω / Bridged
600 x 2
100 V / Ch.
700 x 4
10.4
200 V / Bridged
1400 x 2
Pink noise
8 Ω / Ch.
700 x 4
24.0
(1/4 rated power)
16 Ω / Bridged
1400 x 2
*3)
4 Ω / Ch.
700 x 4
20.8
8 Ω / Bridged
1400 x 2
4 Ω / Ch.
300 x 4
14.0
8 Ω / Bridged
600 x 2
100 V / Ch.
700 x 4
21.4
200 V / Bridged
1400 x 2
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
20 A / 5-20P
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured and specified here is what
is known as the "Active Power" in the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated power. Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is in excess
of max. ratings.
C 28:4
Watt *1)
Thermal Dissipation
230 VAC
In
Out
Dissipated
BTU/hr
0
0
0
0
123
0
123
420
Amp (I)
Watt
5.8
727
350
377
1286
6.5
775
350
425
1450
4.7
529
150
379
1293
5.2
663
350
313
1068
12.0
1589
933
656
2237
10.4
1359
700
659
2249
7.0
843
300
543
1853
10.7
1458
933
525
1790
Level
Load
kCal/hr
0
Standby with remote power off via NomadLink
106
Powered on, idling.
Pink noise
8 Ω / Ch.
324
(1/8 rated power)
16 Ω / Bridged
4 Ω / Ch.
365
8 Ω / Bridged
2 Ω / Ch.
326
4 Ω / Bridged
100 V / Ch.
269
200 V / Bridged
Pink noise
8 Ω / Ch.
564
(1/4 rated power)
16 Ω / Bridged
*3)
4 Ω / Ch.
567
8 Ω / Bridged
2 Ω / Ch.
467
4 Ω / Bridged
100 V / Ch.
451
200 V / Bridged
Mains connector, 230 V CE version
Mains connector, 115 V ETL version
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured and specified here is what
is known as the "Active Power" in the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated power. Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is in excess
of max. ratings.
C 16:4
Line Current *2)
Watt *1)
Rated power
115 VAC
230 VAC
In
Out
0
0
129
0
Amp (I)
Watt
400 x 4
8.6
4.3
526
200
800 x 2
300 x 4
8.2
4.1
485
150
600 x 2
n.r.
n.r.
400 x 4
7.6
3.8
463
200
800 x 2
400 x 4
16.2
8.1
1046
533
800 x 2
300 x 4
15.2
7.6
953
400
600 x 2
n.r.
n.r.
400 x 4
14.4
7.2
944
533
800 x 2
16 A, CEE7
15 A / 5-15P
29
Quick Start Guide
Thermal Dissipation
Dissipated
BTU/hr
kCal/hr
0
0
0
129
440
111
326
1112
280
335
1143
288
263
897
226
513
1749
441
553
1887
475
411
1401
353