Operation Manual Operation Manual C Series Dedicated Installation Amplifiers ▸ C 20:8X ▸ C 10:8X ▸ C 10:4X ▸ C 5:4X Rev. 1.1.4 Item no. OM-CSX...
21. The US National Differences clause 16.3 requires that network cables must be flame rated VW-1. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
All electrical products sold in the EC must be approved for immunity against electromagnetic fields, high voltage flashes, and radio interference. Consult the dealer or an experienced radio/TV technician for help. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
If the dust filters are not clean and the unit malfunctions, any resultant problems will not be covered by the warranty. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
NomadLink / Ethernet network setup ....................11 Operation and Performance ......................... 14 Introduction ............................14 Operation precautions ........................14 Signal flow and headroom........................14 5.3.1 Signal flow blocks ........................14 C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Page 7
Additional documentation ........................31 Current Draw and Thermal Dissipation specification ................32 Signal flow and VPL to output measurements ..................36 Technical Specifications ........................37 Warranty ..............................38 C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Lab.gruppen C Series power amplifiers are designed and built specifically for the unique demands of perma- nent installation applications. C Series amplifiers offer the optimum combination of high-quality audio reproduc- tion, flexible features, ease of installation, and ultimate reliability in normal use.
Your new C Series amplifier incorporates a number of sophisticated technologies – many of them proprietary to Lab.gruppen – that are provided to ensure the best possible performance and many years of reliable operation. Familiarizing yourself with these technologies will prove invaluable in setting up and optimizing your loudspeaker system.
The 35 Hz high-pass filter rolls off low frequencies (6 dB/octave) for greater efficiency and reliability in, for example, 70/100 V high impedance systems where the removal of very low frequency content may be desired. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
NomadLink allows you to remotely power on and power off individual amplifiers or user-definable groups of amplifiers, as well as engage Mute and Solo functions on individual channels. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
3. Installation Unpacking Carefully open the shipping carton and check for any noticeable damage. Every Lab.gruppen amplifier is tested and inspected before leaving the factory and should arrive in perfect condition. If any damage is discovered, please notify the shipping company immediately. Only the consignee may institute a claim with the carrier for damage incurred during shipping.
If you are not 100% confident of your competence to replace the mains plug, engage qualified personnel to do the job. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
In the interests of safety, never disconnect the earth (ground) pin on the AC power cord. Use balanced input connections to avoid hum and interference. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
“Power On” command is received from the network. When the remote switch is off, it is not possible to switch amplifier power on or off using NomadLink network control. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
NomadLink receives phantom specified nominal load, the amplifier channel is able powerfrom the NLB 60E over the network cable. to deliver maximum rated output power. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Bridged Mode - Switches the channel pairs into bridged mode operation (automatic -6 dB gain compensation). When in bridged mode, 2 ohm operation is not recommended. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
NLB 60E unit. The NomadLink connections between amplifiers use standard “straight” Cat-5/RJ45 equipped cables. US National Differences cl.16.3 requires that NomadLink network cables must be rated VW-1. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Page 19
External contact closures can be connected to the GPI connectors on the NLB 60E for control of fire-alarm systems or external power sequencers. For more details, please read the Operation Manual supplied with the NLB 60E. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Page 20
BR.=BRIDGE BRIDGE BRIDGE C+D BRIDGE A+B CLASS 3 WIRING IN OUT NOMADLINK Figure 5.3: Connection details between a PC, the NLB 60E and networked amplifiers C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
VPL (and output amplifier voltage clip if “Soft Clip” activated). This ensures that power output is maintained within the design limits of the amplifier. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Figure 6.4.1: Phoenix-type input connector field Electronically balanced, Phoenix-type inputs are provided on all channels. Follow the +,– and Ground labels when connecting the input signal. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
A (A+B) or C (C+D) respectively. Output speaker cables must be connected to the plus pole on channel A. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Mute. Lowering the VPL setting usually will solve this situation. If the Current Peak Limiter is active or indicates low impedance, lowering the VPL setting can rectify this situation as well. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
If the CPL indicator is lit continuously, then the amplifier is delivering excessive current and is being forced into a current limiting state (output muted). C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
POWER CONTROL 2 will follow the state of the port. If the connection is closed, the amplifier turns on; if the connection is open the amplifier will turn off. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
The VHF protection is NOT a limiter and does not alter the amplifier’s frequency response. It is implemented solely to detect continuous VHF content. The amplifier will always pass VHF peaks at full power, with no effect on musical “transients”. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
When this occurs, the amplifier protects the output stage from damage by muting the output signal and bypassing the circuits. Indication of this fault is a constant orange C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
The C Series amplifiers have very low inrush power as the capacitors are charged slowly and in a controlled manner ensuring that breakers will not trip. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
However, it could indicate acceptable high impedance, such as a sub-bass enclosure with high impedance at a certain frequency. For more detailed signal level indications use the DeviceControl software application. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
NomadLink network cable. Bridge mode (yellow) indicates if two channels are bridged using the DIP-switch on the rear panel. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
C...X Series as well as standard C Series or FP+ amplifiers, each C...X unit should be counted as two devices on the network, with the total device count not to exceed 60 devices per subnet. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Contact your an IT expert or an authoritative source for more details. Below are typical examples of NomadLink network setups: Figure 6.7.4 shows typical examples of NomadLink network setups: C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
NLB 60E. DeviceControl provides comprehensive monitoring of amplifier status as well as control of amplifier power ON/OFF and individual channel mute and solo functions. Please review the DeviceControl Operation Manual for more detailed information. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
C Series amplifiers, you need to look this information up in a table found in the Ap- pendix section of this manual. Input sensitivity also is automatically calculated in the DeviceControl software application. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
In case you didn’t find what you were looking for in this Operation Manual, check out the website at www. labgruppen.com, where you can find a multitude of additional documentation for C Series. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
*2) Current draw gures measured at 230 V. 115 V gures are 230 V gures multiplied by two. Table 7.4a: C 20:8X Current Draw and Thermal Dissipation specifications C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Page 40
*2) Current draw gures measured at 230 V. 115 V gures are 230 V gures multiplied by two. Table 7.4b: C 10:8X Current Draw and Thermal Dissipation specifications C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Page 41
*2) Current draw gures measured at 230 V. 115 V gures are 230 V gures multiplied by two. Table 7.4c: C 10:4X Current Draw and Thermal Dissipation specifications C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Page 42
*2) Current draw gures measured at 230 V. 115 V gures are 230 V gures multiplied by two. Table 7.4d: C 5:4X Current Draw and Thermal Dissipation specifications C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Sensitivity: Gain Vrms -8.7 +38 dBu -5.7 +35 dBu -2.7 +32 dBu +29 dBu Figure 7.5: C...X Series signal flow and VPL to output settings C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Note 5): C 88:4 mains connector: 30 A Twist lock. Note 6): Separate 230 V or 115 V versions available. Not selectable on the amplifier. All specifications are subject to change without notice. C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Lab.gruppen shall not be responsible for any incidental or consequential damages. Lab.gruppen’s responsibil- ity is limited to the product itself. Lab.gruppen takes no responsibility for any loss due to cancellation of any events, or rent of replacement equipment or costs due to a third party’s or customer’s loss of profit, or any other indirect cost or losses however incurred.
Page 46
4. Ship the product prepaid to: Lab.gruppen AB Faktorvägen 1 SE-434 37 Kungsbacka SWEDEN Phone: +46 300 56 28 00 Fax: +46 300 56 28 99 service@labgruppen.com www.labgruppen.com C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4...
Page 48
Operation Manual L A b . G r u P P e n A b ► S W e d e n I n T e r n A T I O n A L C O n T A C T ► I n f O @ L A b G r u P P e n . C O m u S C O n T A C T ►...