Samsung AR18NSFPEWQNEU Service Manual page 75

Split-typeair conditioner
Table of Contents

Advertisement

10-2-18 Current sensor error/Input current sensor error
Indoor display
3-LED DISPLAY
LED1
LED2
Outdoor display
LED ON
LED BLINKING
1. Checklist :
1) Is the PFC Shunt( "R701,R702") resistance value correct? Check the resistor is opened
2) Is the IPM Shunt("R410,R411") resistance value correct? Check the resistor is opened
3) Is there no short or open around "IC451" ?
2. Troubleshooting procedure
Rest
Is the PFC shunt and IPM
shunt resistance value correct?
Is the current sensor error appeared again?
Exchange the Outdoor PBA
Samsung Electronics
7-SEG DISPLAY
LED3
LED OFF
YES
YES
E462
AC Input I_Limit Trip Error
Current sensor error
Input current sensor error
NO
Exchange the Outdoor PBA
NO
Terminate the service
DESCRIPTION
10-21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents