Advertisement

OWNER'S / INSTALLATION MANUAL
AIR CONDITIONER
Read this owner's manual thoroughly before operating the
appliance and keep it handy for reference at all times.
TYPE : WIRED REMOTE CONTROLLER
EN ENGLISH
FR FRANÇAIS
MFL71781801
Rev.01_030421
ES ESPAÑOL
Copyright © 2021 LG Electronics Inc. All rights reserved.
www.lghvac.com
www.lg.com

Advertisement

Table of Contents
loading

Summary of Contents for LG PREMTA200

  • Page 1 Read this owner’s manual thoroughly before operating the appliance and keep it handy for reference at all times. TYPE : WIRED REMOTE CONTROLLER EN ENGLISH FR FRANÇAIS ES ESPAÑOL www.lghvac.com www.lg.com MFL71781801 Rev.01_030421 Copyright © 2021 LG Electronics Inc. All rights reserved.
  • Page 2: Table Of Contents

    Parts Installing the controller STANDARD OPERATION Installation wizard View Screen Standard Operation 14 ADVANCED FUNCTION 16 SCHEDULE 19 ENERGY 20 SETTINGS General setting Air conditioner / Ventilator setting SVC Contents 24 INSTALLER SETTING 28 USING LG THINQ APPLICATION 29 SPECIFICATIONS...
  • Page 3: Safety Instructions

    SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USE Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and follow all safety messages. This is the safety alert symbol.
  • Page 4 Incomplete installation performed by yourself may result in a water leakage, electric shock, and fire. Be sure to only use accessories made by LG which are specifically designed for use with the equipment and have them installed by a professional.
  • Page 5 The Limited Warranty is void and of no effect, and LG will have no liability hereunder to any Customer or third party, to the extent any of the following occur: acts, omissions, and conduct of any and all third parties including, but not limited to, the installing contractor and any repairs, service or maintenance by unauthorized or unqualified persons.
  • Page 6: Prior To Operation

    PRIOR TO OPERATION PRIOR TO OPERATION Preparing for operation PRECAUTION Contact an authorized service technician for repair Contact an installation specialist for installation. or maintenance of this unit. Contact an installation specialist for installation of this unit. The air conditioner is not intended for use by young Usage children or disabled individuals without supervision.
  • Page 7: Parts And Installing The Controller

    PARTS AND INSTALLING THE CONTROLLER PARTS AND INSTALLING THE CONTROLLER Parts Pull the cable from the wall and check the cable direction to install. Align the back cover and check location of two mounting holes on the wall. Prepare by pulling out the communication cable through center hole or top hole.
  • Page 8 PARTS AND INSTALLING THE CONTROLLER NOTE Using Group control Failure to follow the guidelines may result in part Control by connecting 2 to 16 air conditioner indoor damage due to interference with the mechanical. units 6 to one wired remote controller. Be careful not to let the cable pass over the wireless equipment.
  • Page 9: Standard Operation

    STANDARD OPERATION STANDARD OPERATION Installation wizard The installation is finished once the Complete button is tapped. The welcome screen will be displayed after synchronizing with the indoor unit. This may take up to 90 seconds. NOTE If the installation of wizard is not complete, it will run at every booting.
  • Page 10: View Screen

    10 STANDARD OPERATION View Screen The Operating Information screen displays the following according to the indoor unit connected: The Home screen of the wired remote controller Air conditioner consists of the Operating Information screen, Air Quality Level screen and System Monitoring screen. Operating Information General ventilation Air Quality Level...
  • Page 11: Standard Operation

    STANDARD OPERATION Standard Operation Single operation of an air purify purifier. Operation mode Power Increases room temperature Heat quickly. Select the operation mode to set the desired mode. Select OFF from the options list to stop operation. Power It quickly lowers the room Cool temperature.
  • Page 12 12 STANDARD OPERATION Setting temperature Fan speed setting Select the setting temperature or current temperature Select the fan speed icon to select the desired icon. fan speed from the options list. The set temperature area for the current operation Option mode is displayed.
  • Page 13 STANDARD OPERATION NOTE NOTE The air purifying icon is only displayed when air Tap the icon to go to the Error History screen. purifying is on and operating. The total index shows the worst of the 3 dust state Schedule operation values as representative values.
  • Page 14: Advanced Function

    14 ADVANCED FUNCTION ADVANCED FUNCTION Try the advanced function of the product. Detailed settings other than set or cancel is required for this item. Tapping an area above the item changes The product supports this function, but is in an inoperable state. The function can be used just by selecting set or cancel without detailed settings.
  • Page 15 ADVANCED FUNCTION After using the air conditioner for a certain period, the kit attached to the product cleans the filter. Robot Available after 30 seconds of stopping product On / Off Cleaning operation, select whether to operate automatically as an option. If the room is dry, the humidifier installed on the Humidification On / Off...
  • Page 16: Schedule

    16 SCHEDULE SCHEDULE You can use the product by registering the schedule Please set the day of the week for which the from the menu. schedule is to be operated in. Editing of the schedule will be completed and returned to the schedule status screen. NOTE Only one schedule mode can be set for any given time period.
  • Page 17 SCHEDULE Schedule setting NOTE Select the setting icon and use the schedule more During vacation mode, the vacation mode may be efficiently through advanced settings. disabled if operation mode or desired temperature Mode Description is changed. You can hold the existing registered Vacation / Event schedule operation and temporarily change the operation mode to use.
  • Page 18 18 SCHEDULE Display schedule status Schedule hold (temporary schedule) The currently running schedule is temporarily The status of the schedule can be checked on the suspended and is temporarily operating in Operating Information screen of the Home screen. another mode. Displays the types of schedule hold.
  • Page 19: Energy

    ENERGY ENERGY Tap on the energy item in the menu. NOTE You can check energy usage and set power saving Depending on the units selected, the accumulated settings for energy saving. energy usage/power over a day/week/month is displayed. Trend graph You can check the trend of outdoor unit operation rate, indoor temperature, and desired temperature information during the day.
  • Page 20: Settings

    20 SETTINGS SETTINGS Select the Setup icon from the menu. General settings for the use environment configuration, and product settings and SVC setting for using air conditioner/ventilation products are available. General setting Function Description Note & Option Language Set the language you will use English / Español / Français Use type Set the type of use of wired remote controller...
  • Page 21: Air Conditioner / Ventilator Setting

    SETTINGS Function Description Note & Option This is a function to set whether to display the operation mode Display Opposite selection impossible status according to the operation of the outdoor On / Off Mode unit when the cooling/heating mode is selected for products that do not support simultaneous cooling/heating operation.
  • Page 22 22 SETTINGS Product Function Description Option Aircon Vent. This function executes the pairing Wi-Fi pairing function of the Wi-Fi module connected to the indoor unit. The name of each Zone to be used for zone control can be determined by Zone Name directly typing it according to the user's style.
  • Page 23: Svc Contents

    SETTINGS NOTE Depending on the product, some functions may not work. CAUTION Set it to off if the low noise operation time setting and night outdoor cooling setting functions are not used. Low noise operation can reduce cooling capacity. SVC Contents Function Description Service Contact...
  • Page 24: Installer Setting

    24 INSTALLER SETTING INSTALLER SETTING Tap the menu and select the Installer setting. Please enter the password. The configurable items are displayed. * How to know the password If SW version is 1.00.0a, password is 1000. Tap the Magnifier icon in the upper right corner, making it easy to find what you want. - Auto-complete items are displayed based on the characters you enter.
  • Page 25 INSTALLER SETTING Air conditioner Installer setting Product Function Description Option AIRCON Vent It is the function to test the operation at initial Test Run Cool test Run / Heat Test Run installation. Assign a unique address code of indoor units Central Control Address 00~FF when used with central controller.
  • Page 26 26 INSTALLER SETTING Product Function Description Option AIRCON VENTILATOR Step 0~ Step 11 If you step settings, static pressure settings is This function allows you to set the static pressure Static Pressure Step not used. of the duct product by subdividing it into 11 steps. •...
  • Page 27 INSTALLER SETTING Product Function Description Option AIRCON VENTILATOR Estimated Energy This function can set to display energy data which On / Off Display outdoor unit estimated. This is a function to select the use of CN-Port of CN-PTC On / Off indoor unit.
  • Page 28: Using Lg Thinq Application

    28 USING LG THINQ APPLICATION USING LG THINQ APPLICATION You can easily change the desired settings through NOTE the ThinQ App after directly connecting the wired Bluetooth function is not supported. remote controller to the ThinQ App. Even when the “Wired Remote Controller - ThinQ App”...
  • Page 29: Specifications

    In addition to the source code, all referred license terms, warranty disclaimers and copyright notices are available for download. LG Electronics will also provide open source code to you on CD-ROM for a charge covering the cost of performing such distribution (such as the cost of media, shipping, and handling) upon email request to opensource@lge.com.
  • Page 30 THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. Residential Remote Controller specifications Model PREMTA200 2412 MHz ~ 2462 MHz Frequency Range Output Power (Max) < 30 dBm...

Table of Contents