SETTING THE SOLDERING IRON SLEEP TIMER
1. Ensure the soldering iron is in the soldering iron holder.
2. Turn on the power switch.
3. Press and hold the aluminum air flow adjustment knob for about
2 seconds. The time options will light up and the option currently
selected will blink.
4. There are four options for how long the unit sits idle until the sleep
timer kicks in:0, 2, 10 or 30 minutes. If you select 0, the unit will
NOT go into sleep mode (this can reduce the life of your soldering
iron and heating element).
5. Adjust the temperature knob to select the sleep time. When
the display indicates the sleep time you would like, press the
airflow adjustment knob two times to save the setting and exit the
programming mode.
TEMPERATURE CONVERSION
1. Ensure the soldering iron and the hot air gun are in their respective
holders.
2. Turn on the power switches.
3. Press and hold the aluminum air flow adjustment knob for about 2
seconds. The sleep time options will light up, the press the knob
one more time.
4. The °C or °F both light up, the one that is currently chosen will blink.
5. Turn the airflow adjustment knob to select either °C or °F.
6. Press the airflow adjustment knob one time to save the setting and
exit the programming mode.