4 Safety instructions

When using a product from Langer EMV-Technik GmbH, please observe the following safety
instructions to protect yourself from electric shock or the risk of injuries.
Read and follow the instructions in the user manual and keep it in a safe place for later reference. The
device may only be used by personnel who are qualified in the field of EMC and who are fit to work with
and possibly be influenced by disturbance voltages and (electric and magnetic) burst fields.
 Read the operating and safety instructions for all devices used in the set-up.
 Never use any damaged or defective devices.
 Carry out a visual check before using a measurement set-up with a Langer EMV-Technik GmbH
product. Replace any damaged connecting cables before using the product.
 Never leave a product from Langer EMV-Technik GmbH unattended whilst it is in operation.
 The Langer EMV-Technik GmbH product may only be used for its intended purpose. Any other
use is forbidden.
 People with a pacemaker are not allowed to work with this device.
 The test set-up should always be operated via a filtered power supply.
 Attention! Functional near fields and interference emissions may occur when the probe is
operated. The user is responsible for taking appropriate precautions to prevent any inter-
ference with the correct function of products outside the operational EMC environment (in
particular through interference emissions. This can be achieved by:
- observing an appropriate safety distance
- using of shielded or shielding rooms
 The disturbances that are injected into the modules can destroy the device under test (latch-up) if
their intensity is too high. Protect the device under test by:
- increasing the disturbance gradually and stopping when a functional fault occurs
- interrupting the power supply to the device under test in the event of a latch-up.
Attention! Make sure that internal functional faults are visible from outside. The device
under test may be destroyed due to an increase in the injection intensity if the faults are not
visible from outside. Take the following precautions if necessary:
 monitor the representative signals in the device under test
 use a special test software
 monitor visible reaction of the device under test to inputs (reaction test of the device under test).
We cannot assume any liability for the destruction of devices under test!

5 Warranty

Langer EMV-Technik GmbH will remedy any fault due to defective material or defective manufac-
ture, either by repair or by delivery of spare parts, during the statutory warranty period.
This warranty is only granted on condition that:
- the information and instructions in the user manual have been followed.
The warranty will be forfeited if:
- an unauthorized repair is performed on the product,
- the product is modified,
- the product is not used for its intended purpose.