User Manual A100 / A200 / A300 Optical Fibre Probe Copyright Dipl.- Ing. Gunter Langer Nöthnitzer Hang 31 01728 Bannewitz 17.01.2000 Voltage measurement and oscillographic signal tracing in devices and systems under extreme electromagnetic conditions. 2018.10.19 A100-200-300 User manual.doc...
Connection of the probe (example AS 100) to the DUT Starting the AE XXX optical receiver 4 Safety instructions 5 Warranty 6 Technical data System Sensors Receivers 7 Scope of delivery A100-1 / A200-1 / A300-1 (1-channel) set A100-2 / A200-2 / A300-2 (2-channels) set - 2 -...
The task is to correctly measure these relatively slow disturbance signals under extreme RF interference conditions. The A100 / A200 / A300 measurement systems are ideal for these conditions because of their high disturbance immunity.
LANGER DE-01728 Bannewitz A100 / A200 / A300 mail@langer-emv.de EMV-Technik www.langer-emv.com 1.6 Examples of disturbed useful signals - Signals were measured with the AS 100 optical fibre probe - Radiated RF emissions: 250 MHz, 80 % amplitude-modulated by 1 kHz - DUT: operational amplifier circuit;...
Page 5
LANGER DE-01728 Bannewitz A100 / A200 / A300 mail@langer-emv.de EMV-Technik www.langer-emv.com Figure 4 Useful signal without interference Figure 5 Useful signal with 1 kHz disturbance signal Figure 6 Useful signal with 1 kHz disturbance signal limited by the upper rail...
LANGER DE-01728 Bannewitz A100 / A200 / A300 mail@langer-emv.de EMV-Technik www.langer-emv.com 2 Function 2.1 Method of measurement An RF-immune probe (AS 100, AS 110, AS 120, AS 200, AS 300 or AS 350 optical fibre probe), of which the A/D (analog-to-digital) converter is an integral part, is autonomously operated in the DUT without interfering with the DUT's EMC conditions.
LANGER DE-01728 Bannewitz A100 / A200 / A300 mail@langer-emv.de EMV-Technik www.langer-emv.com 3 Operation 3.1 Connection of the probe (example AS 100) to the DUT Figure 8 AS 100 pin assignment Attention: Only connect and disconnect an AS XXX sensor when it is not subjected to any interference.
LANGER DE-01728 Bannewitz A100 / A200 / A300 mail@langer-emv.de EMV-Technik www.langer-emv.com Figure 9 AS 100 connected to the DUT; position the AS 100 on the IC package if there isn't enough free space above 3.2 Starting the AE XXX optical receiver - Connect the AE XXX to the oscilloscope (BNC plug).
Read the operating and safety instructions for all devices used in the set-up. Never use any damaged or defective devices. Carry out a visual check before using a measurement set-up with a Langer EMV-Technik GmbH product. Replace any damaged connecting cables before using the product.
This document may not be copied, reproduced or electronically processed, either in its entirety or in part, without the prior written permission of Langer EMV-Technik GmbH. The management of Langer EMV-Technik GmbH assumes no liability for damage that may arise from using this printed information.