5. Use 3/8" (9.5 mm) nut driver to connect the neutral (white)
wire to the center terminal block post with one of the 10-32
hex nuts.
A. 10-32 hex nut
B. Ground-link screw
C. Line 2 (red)
6. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
7. Securely tighten hex nuts.
NOTE: For power supply cord replacement, use only a power
cord rated at 250 V minimum, 40 A or 50 A that is marked for
use with nominal 1
3
" (3.5 cm) diameter connection opening,
8
with ring terminals and marked for use with ranges.
8. Tighten strain relief screws.
9. Replace terminal block access cover.
10. Plug power cord into grounded outlet (see the "Electrical
Requirements - U.S.A. only" section).
11. Slide range back so that the rear range foot is engaged in the
anti-tip bracket slot.
3-Wire Connection: Power Supply Cord
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the strain relief in the
cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
A. Terminal block
B. Ground-link screw
D. Green ground wire
E. Neutral (center) wire
F. Line 1 (black)
C. UL listed strain relief
D. Power supply cord wires -
large opening
2. Use 3/8" (9.5 mm) nut driver to connect the neutral (white)
wire to the center terminal block post with one of the 10-32
hex nuts.
A. 10-32 hex nut
B. Line 2 (red)
C. Ground-link screw
3. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
4. Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power
cord rated at 250 V minimum, 40 A or 50 A that is marked for
use with nominal 1
3
/
" (3.5 cm) diameter connection opening,
8
with ring terminals and marked for use with ranges.
5. Tighten strain relief screws.
IMPORTANT: Verify the tightness of the hex nuts.
6. Replace terminal block access cover.
7. Plug power cord into grounded outlet (see the "Electrical
Requirements - U.S.A. only" section).
8. Slide range back so that the rear range foot is engaged in the
anti-tip bracket slot.
Direct Wire Installation: Copper or Aluminum Wire
This range may be connected directly to the fuse disconnect or
circuit breaker box. Depending on your electrical supply, make the
required 3-wire or 4-wire connection.
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip
the insulation back 3/8" (1.0 cm) from the end of each wire.
2. Allow enough slack in the wire to easily attach the wiring
terminal block.
3. Complete electrical connection according to your type of
electrical supply (4-wire or 3-wire connection).
D. Neutral (white) wire
E. Line 1 (black)
13